manualshive.com logo in svg
background image

RGBW PUSH-BUTTON CONTROLLER MANUAL

3

3-Phase Fountain Control Panel Field Terminal Connections

 

connections for light kit 

Green,  Black,  White wire 

2.  Wiring RGBW light kit to RGBW control panel.

•  With power disconnected to the RGBW control panel, connect the light kit cord to the RGBW control 

panel wire terminals

•  Terminal #3 to Black wire (line) 
•  Terminal #4 to white wire (neutral) 
•  Terminal #5 to Green wire (ground) 
•  Terminal #6 to Orange wire (DMX+
•  Terminal #7 to Blue wire (DMX common) 
•  Terminal #8 to Red wire (DMX-)

Field connection Terminals in RGBW control panel. 
Connect the Light kit cord connections to these terminals.

2.  Energizing the RGBW control panel

•  With all wiring connections made, light kit installed on the fountain, and fountain in the water, it 

is time to energize the control panels. Energize the fountain panel and set the fountain and light 

timers to ON. This will start the fountain and energize the RGBW control panel.

• 

With the RGBW panel now energized you can follow instructions in Step 6 below to control the lights 

with the RGBW controller.

• 

NOTE: The RGBW control panel must be powered by a GFCI protected 120Vac 60hz circuit. Kasco 

fountain control panels provide this GFCI protected circuit as part of their light kit control circuit. 

Refer to your fountain owner’s manual for setting the timers and installation of fountain control 

panels.

WIRING INSTRUCTIONS (CONT.)