3

Installation requirements:

•  Read and understand all instructions and safety warnings prior to installation and use.

•  Equipment must be installed as required by the instructions.

•  Do not use this equipment outside of its intended purpose, or if site conditions would pose a dangerous installation.  

•  To be installed and operated only by an adult.  Not to be used by children.

•  Never install in areas where swimming is allowed or where people enter the water.  

•  Never use in a swimming pool.  

•  Do not use this equipment for intentional weed removal, sediment removal or dredging.  

•  Follow all local and national electrical wiring rules for the electrical circuit feeding this equipment.  Failure to comply may result 

in injury.  

•  All equipment must be powered from an RCD (residual current device) or GFCI (ground fault circuit interrupter) protected cir-

cuit.   

•  Do not modify any mounting hardware or guarding provided with this equipment.  All guarding purchased with a unit must be 

installed.

•  This equipment is intended to operate without interaction from personnel.  Never to be manipulated, moved, maintained, or ad-

justed while in operation.  Damage or injury could result.

•  The general public must be made aware of the installation and warned of the installation to prevent misuse or interference with 

the equipment.  

•  This equipment is intended to be used in water only.  The equipment should only be operated out of water if required to trouble-

shoot operation and during initial startup of the equipment.  The instructions provide detailed warnings and instructions for such 

activities and should only be performed by a trained person.

Unit Specs

Model

Voltage 

range

Operating 

amps

lock rotor 

amps

4400EJ

208-240

6.5@220V 20@220V

8400EJ

208-240

9.5@220V 40@220V

3.1EJ

208-240 13.2@220V 60@220V

2.3EJ

190

6.4

41

3.3EJ

190

10

69

5.3EJ

190

15.2

98

2.3EHJ

380

3.3

21

3.3EHJ

380

5

34

5.3EHJ

380

7.7

49

Utility requirements:  

The Electrical circuit must be provided to supply sufficient voltage and amperage to the unit.  These ratings are listed in the above 

table (unit specs).  This circuit must also include a disconnect means and short circuit protection.

Содержание 4400EJ

Страница 1: ...Safety Instructions pg2 General description of equipment and function pg2 Intended use and limits of use pg2 Installation requirements pg3 Unit Specs pg3 Utility requirements pg3 Quick Disconnect Ins...

Страница 2: ...ase motor control motor starter with overload and short circuit protection must be provided at time of installation 3 phase units 2 3 3 3 5 3 require a startup test after wiring to ensure proper rotat...

Страница 3: ...talled This equipment is intended to operate without interaction from personnel Never to be manipulated moved maintained or ad justed while in operation Damage or injury could result The general publi...

Страница 4: ...slot for a flat blade screwdriver in the center of the insert Note The inserts have a LEFT HAND THREAD and should be turned clockwise to remove STEP TWO Remove the gland nut and gland from the rear of...

Страница 5: ...onal removal your quick disconnect includes an optional water tight cover Simply separate the quick disconnect and insert the sealing cover into the large blue nut half and tighten firmly Strain Relie...

Страница 6: ...O D of Cord Grey 7 9mm White 9 11mm Black 11 13mm Yellow 13 15mm Kasco 50 Hz Equipment Wire Size Chart Model Cord length 10m 30m 60m 90m 4400EJ 1 5mm 2 1 5mm 2 2 5mm 2 4mm 2 8400EJ 1 5mm 2 2 5mm 2 4mm...

Страница 7: ...Washer 3 840325 4 Float Single Piece 1 See Table Below 5 Interchangeable nozzles 5 See Nozzles Section 6 Nozzle oring 1 841217 7 Large JF Unit Assembly 1 See Table Below 8 Bottom Screen 1 See Table B...

Страница 8: ...8 1 2 4 7 3 10 11 1 2 3 Dedicated power cord channel Align with Cord Assembly Instructions Align slots with threaded holes Leave gap...

Страница 9: ...9 5 4 8 5 3EJ 9 Tighten 3 screws Twist Power cord cord with strain relief cord without strain relief OR cable tie mesh screen 5 3EJ...

Страница 10: ...2 3 2 4 8400 2 3 3 5 3 3 1 3 3 4 9 2 7 5 3 5 8 3 Spruce 5 4400 4 7 2 1 8400 2 3 6 6 2 7 3 1 3 3 7 2 7 5 3 7 9 2 7 Redwood 5 and 6 4400 4 9 1 5 8400 2 3 6 9 1 8 3 1 3 3 7 2 1 8 5 3 8 1 1 8 Pre Installe...

Страница 11: ...11 Balsam 1 Linden 1 Birch 4 Spruce 5 Redwood 5 Balsam Linden Oring dielectric grease Nozzle Assembly...

Страница 12: ...are in the OFF position 4 Connect electrical service to your control panel as shown in the electrical schematic that came with the panel 5 Connect the unit power cord to the panel as shown in the elec...

Страница 13: ...cantly you may need to suspend a small weight 30cm of 2 54cm galvanize pipe works well at the mid point of the rope to take up any slack as the water level drops The weight should be light enough so t...

Страница 14: ...in a location that is out of the sun and cool but above 0o C CLEANING Equipment should be removed from the water at least once per year at the end of the season in cold climates to clean the exterior...

Страница 15: ...from electrical power Check the propeller Impeller for any chipping or damage that would cause the unit to not operate properly Refer to installation instructions for assembly Replace propeller impel...

Отзывы: