CAUTION 

 

 

 

 

        

  NOTICE (NOTE)

These international safety symbols are used throughout this manual to inform the end user, installer, and owner of important safety 

information and notices for safe and effective use of the equipment.

Important Safety Instructions

 CAUTION

•  Under NO circumstances should anyone enter the water with the electrical equipment plugged in and/or in operation.  It is 

NEVER recommended to enter the water with the equipment in operation.

•  Caution should be used when dealing with any electrical equipment with moving parts.

•  NEVER run the unit out of water.  It will damage the seals and create a dangerous situation for the operator.

•  Extreme caution should be used around water, especially cold water, such as in Spring, Fall, and Winter, which poses a 

hazard in and of itself.

•  NEVER lift or drag the unit by the power or light cord.  If you need to pull the unit to the side of the pond, use the 

anchoring ropes.

• 

Do not use waders in deep ponds/lakes or ponds/lakes with drop-offs, drastic slopes, or soft bottom material.

•  Do not use boats that tip easily for fountain installation, such as a canoe, and follow all boating safety rules and 

regulations, including wearing a PFD. (Personal Flotation Device)

•  The unit is supplied with an internal grounding conductor.  To reduce the risk of electrical shock, be certain that the unit is 

plugged/connected to an approved RCD (GFCI) protected circuit.  

•  A properly sized 3 phase motor control (motor starter) with overload and short circuit protection must be provided at time 

of installation.

•  3 phase units (2.3, 3.3, 5.3) require a startup test after wiring to ensure proper rotation of the impeller.  If the impeller is 

rotating in the opposite direction, the unit will not perform properly and internal damage to the unit may occur.  (See 3 

phase startup procedure)

• 

Means for disconnection must be incorporated in the fixed wiring in accordance with local and national wiring rules to 

prevent accidental start.

• 

Consult a qualified electrician for electrical installation.

General description of equipment and function

Fountain/decorative aerator

Electrically driven submersible pump designed to improve water quality with water movement and aeration in a decorative display.

Intended use and limits of use

Kasco equipment is only intended for specific uses as detailed in this owner’s manual.  Intentional misuse could result in injury, dam

-

age to the product, and surrounding property.  

Intended uses are as follows:

Fountains/decorative aerators:  To provide aeration and a decorative display to ponds, lakes, and similar bodies of water.  Fountains 

and decorative aerators are provided with additional guarding to prevent accidental contact while operating.

Installation, adjustment, maintenance, and removal of this equipment should be limited to experienced maintenance persons or trained 

professionals.  If you are not sure how to install or operate any Kasco products call your local distributor, contact an electrician, or 

contact Kasco customer service at www.kascomarine.com for further assistance. 

Содержание 4400EJ

Страница 1: ...Safety Instructions pg2 General description of equipment and function pg2 Intended use and limits of use pg2 Installation requirements pg3 Unit Specs pg3 Utility requirements pg3 Quick Disconnect Ins...

Страница 2: ...ase motor control motor starter with overload and short circuit protection must be provided at time of installation 3 phase units 2 3 3 3 5 3 require a startup test after wiring to ensure proper rotat...

Страница 3: ...talled This equipment is intended to operate without interaction from personnel Never to be manipulated moved maintained or ad justed while in operation Damage or injury could result The general publi...

Страница 4: ...slot for a flat blade screwdriver in the center of the insert Note The inserts have a LEFT HAND THREAD and should be turned clockwise to remove STEP TWO Remove the gland nut and gland from the rear of...

Страница 5: ...onal removal your quick disconnect includes an optional water tight cover Simply separate the quick disconnect and insert the sealing cover into the large blue nut half and tighten firmly Strain Relie...

Страница 6: ...O D of Cord Grey 7 9mm White 9 11mm Black 11 13mm Yellow 13 15mm Kasco 50 Hz Equipment Wire Size Chart Model Cord length 10m 30m 60m 90m 4400EJ 1 5mm 2 1 5mm 2 2 5mm 2 4mm 2 8400EJ 1 5mm 2 2 5mm 2 4mm...

Страница 7: ...Washer 3 840325 4 Float Single Piece 1 See Table Below 5 Interchangeable nozzles 5 See Nozzles Section 6 Nozzle oring 1 841217 7 Large JF Unit Assembly 1 See Table Below 8 Bottom Screen 1 See Table B...

Страница 8: ...8 1 2 4 7 3 10 11 1 2 3 Dedicated power cord channel Align with Cord Assembly Instructions Align slots with threaded holes Leave gap...

Страница 9: ...9 5 4 8 5 3EJ 9 Tighten 3 screws Twist Power cord cord with strain relief cord without strain relief OR cable tie mesh screen 5 3EJ...

Страница 10: ...2 3 2 4 8400 2 3 3 5 3 3 1 3 3 4 9 2 7 5 3 5 8 3 Spruce 5 4400 4 7 2 1 8400 2 3 6 6 2 7 3 1 3 3 7 2 7 5 3 7 9 2 7 Redwood 5 and 6 4400 4 9 1 5 8400 2 3 6 9 1 8 3 1 3 3 7 2 1 8 5 3 8 1 1 8 Pre Installe...

Страница 11: ...11 Balsam 1 Linden 1 Birch 4 Spruce 5 Redwood 5 Balsam Linden Oring dielectric grease Nozzle Assembly...

Страница 12: ...are in the OFF position 4 Connect electrical service to your control panel as shown in the electrical schematic that came with the panel 5 Connect the unit power cord to the panel as shown in the elec...

Страница 13: ...cantly you may need to suspend a small weight 30cm of 2 54cm galvanize pipe works well at the mid point of the rope to take up any slack as the water level drops The weight should be light enough so t...

Страница 14: ...in a location that is out of the sun and cool but above 0o C CLEANING Equipment should be removed from the water at least once per year at the end of the season in cold climates to clean the exterior...

Страница 15: ...from electrical power Check the propeller Impeller for any chipping or damage that would cause the unit to not operate properly Refer to installation instructions for assembly Replace propeller impel...