3020379

 

ANSI/UL 778: 2016

 

Ed.6+R:22Feb2017

 

CSA C22.2 #108: 2014 Ed.5

 

 

Kasco Marine, Inc. 

800 Deere Rd. 

Prescott, WI 54021 
PH (715) 262-4488 

www.kascomarine.com 

Manual Number 

884170 

 
 

Rev. 7-2020 

Содержание 2400VFX

Страница 1: ...ators 2400VFX 3400VFX 4400VFX 3400HVFX 4400HVFX 3020379 ANSI UL 778 2016 Ed 6 R 22Feb2017 CSA C22 2 108 2014 Ed 5 Kasco Marine Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 www kascomarine com Manual Number 884170 Rev 7 2020 ...

Страница 2: ...or needs and want you to be completely satisfied with your purchase Important Safety Instructions Please read and follow these extremely important safety and handling instructions for your Kasco equipment Following these instructions will help ensure your safety and the quality performance of your equipment Under NO circumstances should anyone enter the water with the electrical equipment plugged ...

Страница 3: ... specific for your model and size of aerator Note Use a nylon tie to help keep the power cords for the unit and lights free of the propeller by tying each cord to either side of the float If you have a light kit make sure that the unit cord is tied to one side of the float and the light cord to the other for balance Note It is extremely important to test the GFI breaker in the control panel upon e...

Страница 4: ...dwire C 85 plug into or hardwire C85 4400VFX 110 120 11 3 40 C 25 plug in Plug into C 25 4400HVFX 208 240 5 7 20 Hardwire C 85 plug into or hardwire C85 VX Pattern Sizes NOTE Pattern sizes listed are approximate Variations in voltage caused by regional electrical differences or voltage drop due to long power cords may result in reduced pattern sizes Model Height Width 2400VFX 5 15 3400VFX 5 5 21 3...

Страница 5: ...opes optional 10 x 1 long or longer screw s for mounting the C 25 3 or C 85 4 7 16 Socket and Ratchet 7 16 Wrench 11 32 wrench for 8 fasteners Item Part Qty 1 Aerator 1 2 Float 242001 1 3 1 4 20 x 3 1 2 Phillips Pan Head Screw 251210 4 4 1 4 split washers 840537 7 5 1 4 3 4 OD Flat Washer 251300 10 6 1 4 20 x 1 3 4 Hex Head Bolt 475630 3 7 Bottom Screen Section 361540 3 8 1 4 20 Nut 840536 3 9 8 n...

Страница 6: ...otch Align bolt holes with legs Lock washer goes 2 between bolt and flat washer Tighten down in 4 places 3 Turn over Bring bottom screen sections together 4 Tighten down in 6 places to hold the screen together For quicker assembly Use cable tie instead Secure the bottom screen 5 to the float in 3 places Make sure cord is sticking out of notch ...

Страница 7: ...install in the pond go to Installation instructions Light Kits can also be installed at this time go to Light kit instructions 6 Turn upright Secure power cord to rope hole OR With Strain Relief Without Strain Relief ...

Страница 8: ...x A 6 foot deep pond would require an anchor 18 feet horizontally from the float VFX Installation Instructions Alternate Installation Instructions In ponds where the water level fluctuates significantly you may need to suspend a small weight 12 of 1 galvanize pipe works well at the mid point of the rope to take up any slack as the water level drops The weight should be light enough so the aerator ...

Страница 9: ...equires at least a 30amp protected circuit feeding the panel C 95 panel requires at least a 40amp protected circuit feeding the panel Connect your power feed as detailed in the wiring diagram provided with this panel L1 connects to Terminal 1 L2 connects to Terminal 2 N connects to Terminal N G connects to Terminal GROUND located on chassis plate Be sure to provide adequately sized power conductor...

Страница 10: ...on 2 If the G F C I tests okay restore power by pushing the RESET button back in THE RESET BUTTON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT LOCKS AND RE MAINS DEPRESSED AFTER PRESSURE HAS BEEN REMOVED DANGER IF RESET BUTTON DOES NOT POP OUT IF TEST LAMP REMAINS LIT WHEN RESET BUTTON DOES POP OUT OR IF THE G F C I FAILS TO RESET PROPERLY DO NOT USE TIMER CONTACT A QUALIFIED SERVICE TECHNI...

Страница 11: ...ter ring position for the entire period that the aerator is to be turned ON i e 15min for each tripper on the 24 hour dial When the tripper is pushed to the inside the switch is in the OFF position PROGRAMMING WITH MANUAL OVERRIDE SWITCH Your Timer may have a 3 way manual switch or a 2 way manual switch AUTOMATIC MODE In order to operate the time clock in the automatic mode the manual switch must ...

Страница 12: ...12 ...

Страница 13: ...onger and can actually make ice thicker on the pond lake Storage over winter is best in a location that is out of the sun and cool but above 32OF When storing units during the offseason it is important to store them upside down if they are going to be sitting for long periods of time Units that sit upright on a shelf for many months or even years have a greater likelihood of seals drying out Stori...

Страница 14: ... be accepted for warranty repair The power cord and all other components must be returned with the motor as originally assembled Any missing parts will be replaced at the customer s expense and if determined to have caused the failure could void the entire warranty Some parts are essential for structural support during shipping and others such as the power cord are essential to properly diagnose p...

Страница 15: ...horized Repair Center My Aerator turns itself off and back on without the timer and without tripping the GFI breaker single phase units only Each Kasco aerator has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down it will start back up If you are noticing these symptoms the unit should be unplugged immediately because the Thermal Overload will ...

Страница 16: ...16 ...

Страница 17: ... unit unless otherwise instructed A fee of 60 per hour will be assessed for cleaning excessively dirty units and float disassembly Refer to the Owner s manual for easy to follow troubleshooting rule out site issue Note Contact Information Should be that of the person or company to contact for repair Company First Name Last Name Address City State Zip code Phone Alternate Phone Email Address Prefer...

Страница 18: ...and keep for your records Model Ex 5 1VX _______________________________ Serial Ex 5101VX511725 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ___________________________ ...

Отзывы: