Inspect the panel for any damage and any components that may have loosened during shipping. Control panel must be 
installed a minimum of 5ft (3m in Canada) from the inside wall of the pond, unless separated from the body of water by a 
fence wall, or other permanent barrier that will make the unit inaccessible to persons in the water. Install the control panel 
to a post structure, side of a building, or other reliable means. This structure must support the panel and prevent 

movement/flexing of the panel. Use #10 x 1” or longer screws in the mounting points of the control panel to secur

e to the 

post structure. NOTE: The control panel must be hung upright to be waterproof. It is also advised to mount the panel out of 
direct sunlight if possible by mounting the panel in a North direction. Also, mount the panel above the potential flood plain 
to prevent water entry during a possible flood event. 

2.

 

Set Timer in the control panel to desired ON and OFF times per the Instructions for each specific timer. 

3.

 

Follow all local and national electrical codes for this installation and Consult a qualified electrician or service 
person if needed.

 

a.

 

(For 120V Installations) Plug the aerator cord into the C-

25 outlet labeled “UNIT”. If lights are included, plug the 

Transformer cord into the C-

25 outlet labeled “LIGHT”. Now you are ready to plug the 

C-25 into the 120V power 

supply on the post and ENJOY YOUR NEW KASCO AERATOR!

 

b.

 

(For 240V Installations 

 3400H, 4400H) All electrical connections to this panel must be made with proper strain 

relief cord grip fittings or with conduit connections as required by local and national electric codes. The bottom of 
the enclosure is reserved for field installation of these connections.

 

i.

 

C85 / C95 non-metallic control panel:

 Incoming power connection: (Power feed) This control panel 

requires a 240V or 208V - 4 wire service (L1, L2, N, & G) and must be fed with a power circuit protected 
by a circuit breaker or a fused disconnect switch to provide circuit protection and a disconnection 
means. C-85 panel requires at least a 30amp protected circuit feeding the panel. C-95 panel requires at 
least a 40amp protected circuit feeding the panel. Connect your power feed as detailed in the wiring 
diagram provided with this panel. L1 connects to Terminal #1 L2 connects to Terminal #2 N connects to 
Terminal N G connects to Terminal GROUND - located on chassis plate Be sure to provide adequately 
sized power conductors to prevent excessive voltage drop. Consult with your electrician to properly size 
power feed conductors. Use copper conductors only. Aerator power cord connection: Your aerator 
(pump) will be provided with a flexible power cord for connection to this control panel. If the power cord 
has a plug, you will need to cut it off. The power cord conductors (black, white, green) will need to be 

stripped back 1/2”. The outer black jacket should be stripped back at least 3inches. Follow the 

connection diagram for terminating these three wires to the terminal blocks in the control panel. Black 
connects to Terminal #4, White connects to Terminal #5, Green connects to Terminal G.

 

 

1.

 

This control panel requires a hardwire connection for the light kit(s). To connect the light kit(s) 
you will need to cut off the power cord plug that is molded to the light kit power cord. Strip back 
the black outer jacket of the light kit power cord at least 3 inches to reveal the three internal 
wires of the power cord. (black, white, and green conductors). These three wires will need to be 

stripped back 1/2”. Follow t

he connection diagram for terminating these three wires to the 

terminal blocks in the control panel. Light kit connections: Black connects to Terminal #6, White 
connects to Terminal #7, Green connects to Terminal G. 

4.

 

Test the GFCB with the test button now and every 30 days. If lights are installed, they can now be installed per 
Instructions included with the lights. Once completed, power can be restored to the panel. Record the following data while 
the Aerator is operating in the water under load: 

Voltage: 

L1-L2 ________ 

L1-N _________ 

L2-N _________ 

Amperage: 

L1 __________ 

L2 __________ 

Date installed _____/_____/_____ 

 
Any unauthorized modifications to this control panel will void the UL listing and the Kasco warranty. 

Control Panel Installation 

Содержание 2400VFX

Страница 1: ...ators 2400VFX 3400VFX 4400VFX 3400HVFX 4400HVFX 3020379 ANSI UL 778 2016 Ed 6 R 22Feb2017 CSA C22 2 108 2014 Ed 5 Kasco Marine Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 www kascomarine com Manual Number 884170 Rev 7 2020 ...

Страница 2: ...or needs and want you to be completely satisfied with your purchase Important Safety Instructions Please read and follow these extremely important safety and handling instructions for your Kasco equipment Following these instructions will help ensure your safety and the quality performance of your equipment Under NO circumstances should anyone enter the water with the electrical equipment plugged ...

Страница 3: ... specific for your model and size of aerator Note Use a nylon tie to help keep the power cords for the unit and lights free of the propeller by tying each cord to either side of the float If you have a light kit make sure that the unit cord is tied to one side of the float and the light cord to the other for balance Note It is extremely important to test the GFI breaker in the control panel upon e...

Страница 4: ...dwire C 85 plug into or hardwire C85 4400VFX 110 120 11 3 40 C 25 plug in Plug into C 25 4400HVFX 208 240 5 7 20 Hardwire C 85 plug into or hardwire C85 VX Pattern Sizes NOTE Pattern sizes listed are approximate Variations in voltage caused by regional electrical differences or voltage drop due to long power cords may result in reduced pattern sizes Model Height Width 2400VFX 5 15 3400VFX 5 5 21 3...

Страница 5: ...opes optional 10 x 1 long or longer screw s for mounting the C 25 3 or C 85 4 7 16 Socket and Ratchet 7 16 Wrench 11 32 wrench for 8 fasteners Item Part Qty 1 Aerator 1 2 Float 242001 1 3 1 4 20 x 3 1 2 Phillips Pan Head Screw 251210 4 4 1 4 split washers 840537 7 5 1 4 3 4 OD Flat Washer 251300 10 6 1 4 20 x 1 3 4 Hex Head Bolt 475630 3 7 Bottom Screen Section 361540 3 8 1 4 20 Nut 840536 3 9 8 n...

Страница 6: ...otch Align bolt holes with legs Lock washer goes 2 between bolt and flat washer Tighten down in 4 places 3 Turn over Bring bottom screen sections together 4 Tighten down in 6 places to hold the screen together For quicker assembly Use cable tie instead Secure the bottom screen 5 to the float in 3 places Make sure cord is sticking out of notch ...

Страница 7: ...install in the pond go to Installation instructions Light Kits can also be installed at this time go to Light kit instructions 6 Turn upright Secure power cord to rope hole OR With Strain Relief Without Strain Relief ...

Страница 8: ...x A 6 foot deep pond would require an anchor 18 feet horizontally from the float VFX Installation Instructions Alternate Installation Instructions In ponds where the water level fluctuates significantly you may need to suspend a small weight 12 of 1 galvanize pipe works well at the mid point of the rope to take up any slack as the water level drops The weight should be light enough so the aerator ...

Страница 9: ...equires at least a 30amp protected circuit feeding the panel C 95 panel requires at least a 40amp protected circuit feeding the panel Connect your power feed as detailed in the wiring diagram provided with this panel L1 connects to Terminal 1 L2 connects to Terminal 2 N connects to Terminal N G connects to Terminal GROUND located on chassis plate Be sure to provide adequately sized power conductor...

Страница 10: ...on 2 If the G F C I tests okay restore power by pushing the RESET button back in THE RESET BUTTON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT LOCKS AND RE MAINS DEPRESSED AFTER PRESSURE HAS BEEN REMOVED DANGER IF RESET BUTTON DOES NOT POP OUT IF TEST LAMP REMAINS LIT WHEN RESET BUTTON DOES POP OUT OR IF THE G F C I FAILS TO RESET PROPERLY DO NOT USE TIMER CONTACT A QUALIFIED SERVICE TECHNI...

Страница 11: ...ter ring position for the entire period that the aerator is to be turned ON i e 15min for each tripper on the 24 hour dial When the tripper is pushed to the inside the switch is in the OFF position PROGRAMMING WITH MANUAL OVERRIDE SWITCH Your Timer may have a 3 way manual switch or a 2 way manual switch AUTOMATIC MODE In order to operate the time clock in the automatic mode the manual switch must ...

Страница 12: ...12 ...

Страница 13: ...onger and can actually make ice thicker on the pond lake Storage over winter is best in a location that is out of the sun and cool but above 32OF When storing units during the offseason it is important to store them upside down if they are going to be sitting for long periods of time Units that sit upright on a shelf for many months or even years have a greater likelihood of seals drying out Stori...

Страница 14: ... be accepted for warranty repair The power cord and all other components must be returned with the motor as originally assembled Any missing parts will be replaced at the customer s expense and if determined to have caused the failure could void the entire warranty Some parts are essential for structural support during shipping and others such as the power cord are essential to properly diagnose p...

Страница 15: ...horized Repair Center My Aerator turns itself off and back on without the timer and without tripping the GFI breaker single phase units only Each Kasco aerator has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down it will start back up If you are noticing these symptoms the unit should be unplugged immediately because the Thermal Overload will ...

Страница 16: ...16 ...

Страница 17: ... unit unless otherwise instructed A fee of 60 per hour will be assessed for cleaning excessively dirty units and float disassembly Refer to the Owner s manual for easy to follow troubleshooting rule out site issue Note Contact Information Should be that of the person or company to contact for repair Company First Name Last Name Address City State Zip code Phone Alternate Phone Email Address Prefer...

Страница 18: ...and keep for your records Model Ex 5 1VX _______________________________ Serial Ex 5101VX511725 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ___________________________ ...

Отзывы: