Single phase aerators are supplied with an internal grounding conductor and/or a grounding-type attachment plug.  To reduce the 
risk of electrical shock, be certain the aerator is properly connected to the  
Kasco supplied control panel.  (refer to the C-25,  
C-85 & C-95 Control instructions)  

 

3 phase aerators (2.3VFX, 5.3VFX) require a startup test after wiring to ensure proper rotation of the propeller.  If the propeller is 
rotating in the opposite direction, the unit will not perform properly and internal damage to the unit may occur.  (See 3 phase startup 
procedure) 

 

Control panels must be installed a minimum of 5ft(3m in Canada) from the inside wall of the pond, unless separated from the body of 
water by a fence wall, or other permanent barrier that will make the unit inaccessible to persons in the water.   

 

Control panels must be installed by a qualified electrician. 

 

Ground Fault Circuit Interrupters (GFCI) should be tested upon each installation and every month thereafter to ensure proper 
operation. 

General Owner’s Instructions

 

INSPECT THE SHIPMENT 
Immediately inspect your Kasco Aerator shipment for any visible damages.  Also cross reference the parts supplied with the Parts 

Included sheet to check for shortages.  Shortages should be reported immediately to your Kasco Marine distributor or representative 
and damages reported to your carrier and Kasco Marine. 

CAUTION 
WARNING:  Under NO circumstances should anyone enter the water with the unit in operation.  Always operate the unit in the water 

and keep people and objects clear of the propeller.  Do not lift or pull the unit by the electrical cord.  Always use extreme caution 
around electrical equipment and water situations. 

ASSEMBLY & INSTALLATION 
Please see the proper Assembly and Installation Instructions enclosed in this manual.  Each is specific for your model and size of 

aerator.  Note:  Use a nylon tie to help keep the power cords for the unit and lights free of the propeller by tying each cord to either side 
of the float. If you have a light kit, make sure that the unit cord is tied to one side of the float and the light cord to the other for balance.  
Note: It is extremely important to test the GFI breaker in the control panel upon each installation/reinstallation of the unit to ensure 
proper functioning. 

WARRANTY 
Kasco aerators are the result of over 35 years of design and engineering.  Kasco products are built to withstand the toughest 

conditions.  Kasco Marine backs each VFX model aerator with either a 2 Year or 3 Year Warranty depending on the model.  This 
warranty covers any and all manufacturers defects within the warranty period from the date of purchase (See Warranty Section).   

USE AND OPERATION 
Kasco aerators are designed and engineered for continuous duty, such as on fish farms or other aquaculture applications, or on-

demand use, as needed in a recreational water feature. During flotation operation, the water is pulled from 360 degrees around the unit 
and from below the unit.  The water is pulled upward and thrust through the flotation collar into the air. Your Kasco Marine aerator is 
ready for immediate use (after installation).  Make sure to keep the motor housing clean from hard water deposits and/or algae. (See 
Maintenance Recommendations.) It is extremely important that proper and sufficient voltage is supplied to the aerator motor.  Unit 
should be protected by a GFCI.  Control panels must be installed by a qualified electrician.  (See Installation instructions). 

UNIT STORAGE 
When storing units during the offseason, it is important to store them upside down if they are going to be sitting for long periods of time.  

Units that sit upright on a shelf for many months, or even years have a greater likelihood of seals drying out.  Storing upside down will 
ensure oil is lubricating the seals and prevent drying. 

 

Содержание 2400VFX

Страница 1: ...ators 2400VFX 3400VFX 4400VFX 3400HVFX 4400HVFX 3020379 ANSI UL 778 2016 Ed 6 R 22Feb2017 CSA C22 2 108 2014 Ed 5 Kasco Marine Inc 800 Deere Rd Prescott WI 54021 PH 715 262 4488 www kascomarine com Manual Number 884170 Rev 7 2020 ...

Страница 2: ...or needs and want you to be completely satisfied with your purchase Important Safety Instructions Please read and follow these extremely important safety and handling instructions for your Kasco equipment Following these instructions will help ensure your safety and the quality performance of your equipment Under NO circumstances should anyone enter the water with the electrical equipment plugged ...

Страница 3: ... specific for your model and size of aerator Note Use a nylon tie to help keep the power cords for the unit and lights free of the propeller by tying each cord to either side of the float If you have a light kit make sure that the unit cord is tied to one side of the float and the light cord to the other for balance Note It is extremely important to test the GFI breaker in the control panel upon e...

Страница 4: ...dwire C 85 plug into or hardwire C85 4400VFX 110 120 11 3 40 C 25 plug in Plug into C 25 4400HVFX 208 240 5 7 20 Hardwire C 85 plug into or hardwire C85 VX Pattern Sizes NOTE Pattern sizes listed are approximate Variations in voltage caused by regional electrical differences or voltage drop due to long power cords may result in reduced pattern sizes Model Height Width 2400VFX 5 15 3400VFX 5 5 21 3...

Страница 5: ...opes optional 10 x 1 long or longer screw s for mounting the C 25 3 or C 85 4 7 16 Socket and Ratchet 7 16 Wrench 11 32 wrench for 8 fasteners Item Part Qty 1 Aerator 1 2 Float 242001 1 3 1 4 20 x 3 1 2 Phillips Pan Head Screw 251210 4 4 1 4 split washers 840537 7 5 1 4 3 4 OD Flat Washer 251300 10 6 1 4 20 x 1 3 4 Hex Head Bolt 475630 3 7 Bottom Screen Section 361540 3 8 1 4 20 Nut 840536 3 9 8 n...

Страница 6: ...otch Align bolt holes with legs Lock washer goes 2 between bolt and flat washer Tighten down in 4 places 3 Turn over Bring bottom screen sections together 4 Tighten down in 6 places to hold the screen together For quicker assembly Use cable tie instead Secure the bottom screen 5 to the float in 3 places Make sure cord is sticking out of notch ...

Страница 7: ...install in the pond go to Installation instructions Light Kits can also be installed at this time go to Light kit instructions 6 Turn upright Secure power cord to rope hole OR With Strain Relief Without Strain Relief ...

Страница 8: ...x A 6 foot deep pond would require an anchor 18 feet horizontally from the float VFX Installation Instructions Alternate Installation Instructions In ponds where the water level fluctuates significantly you may need to suspend a small weight 12 of 1 galvanize pipe works well at the mid point of the rope to take up any slack as the water level drops The weight should be light enough so the aerator ...

Страница 9: ...equires at least a 30amp protected circuit feeding the panel C 95 panel requires at least a 40amp protected circuit feeding the panel Connect your power feed as detailed in the wiring diagram provided with this panel L1 connects to Terminal 1 L2 connects to Terminal 2 N connects to Terminal N G connects to Terminal GROUND located on chassis plate Be sure to provide adequately sized power conductor...

Страница 10: ...on 2 If the G F C I tests okay restore power by pushing the RESET button back in THE RESET BUTTON MUST BE PUSHED FIRMLY AND FULLY INTO PLACE UNTIL IT LOCKS AND RE MAINS DEPRESSED AFTER PRESSURE HAS BEEN REMOVED DANGER IF RESET BUTTON DOES NOT POP OUT IF TEST LAMP REMAINS LIT WHEN RESET BUTTON DOES POP OUT OR IF THE G F C I FAILS TO RESET PROPERLY DO NOT USE TIMER CONTACT A QUALIFIED SERVICE TECHNI...

Страница 11: ...ter ring position for the entire period that the aerator is to be turned ON i e 15min for each tripper on the 24 hour dial When the tripper is pushed to the inside the switch is in the OFF position PROGRAMMING WITH MANUAL OVERRIDE SWITCH Your Timer may have a 3 way manual switch or a 2 way manual switch AUTOMATIC MODE In order to operate the time clock in the automatic mode the manual switch must ...

Страница 12: ...12 ...

Страница 13: ...onger and can actually make ice thicker on the pond lake Storage over winter is best in a location that is out of the sun and cool but above 32OF When storing units during the offseason it is important to store them upside down if they are going to be sitting for long periods of time Units that sit upright on a shelf for many months or even years have a greater likelihood of seals drying out Stori...

Страница 14: ... be accepted for warranty repair The power cord and all other components must be returned with the motor as originally assembled Any missing parts will be replaced at the customer s expense and if determined to have caused the failure could void the entire warranty Some parts are essential for structural support during shipping and others such as the power cord are essential to properly diagnose p...

Страница 15: ...horized Repair Center My Aerator turns itself off and back on without the timer and without tripping the GFI breaker single phase units only Each Kasco aerator has a Thermal Overload built in that will turn the unit off when it overheats Once the unit has cooled down it will start back up If you are noticing these symptoms the unit should be unplugged immediately because the Thermal Overload will ...

Страница 16: ...16 ...

Страница 17: ... unit unless otherwise instructed A fee of 60 per hour will be assessed for cleaning excessively dirty units and float disassembly Refer to the Owner s manual for easy to follow troubleshooting rule out site issue Note Contact Information Should be that of the person or company to contact for repair Company First Name Last Name Address City State Zip code Phone Alternate Phone Email Address Prefer...

Страница 18: ...and keep for your records Model Ex 5 1VX _______________________________ Serial Ex 5101VX511725 ______________________________ Purchase Date _____________________ Purchased From ___________________________________ Registration Date ___________________________ ...

Отзывы: