Description

   ..........................................................................................................   1

   

Features

   ...............................................................................................................   3

   

Installation

   ...........................................................................................................   3

   

Sounds and Lighting

   ...............................................................................................   3

   

Rest to Factory Default

   ..................................................................................   3

   

Technical Specifications

   ...............................................................................   4

   

Wiring Colours

   ...................................................................................................   4

   

Wiring Diagram

   .................................................................................................   4

   

Common Power Supply

   ..................................................................................................   4

   

Special Power Supply

   ......................................................................................................   4

   

Manager Operation

   .........................................................................................   5

   

Logging User Identification Numbers

   .............................................................   5

   

User Management with Manager Cards

   .................................................   5

   

Adding a Fingerprint or Keycard User

   ............................................................   5

   

Removing Users

   .......................................................................................................   5

   

User Management with Remote Control

   ................................................   5

   

Enter programming mode

   ....................................................................................   5

   

Adding a fingerprint user-Auto generated user ID Number

   ...................   5

   

Adding a Fingerprint/ Keycard user - Appointing specific ID number 
to user

   ...........................................................................................................................   6

   

Removing Fingerprint or Keycard User Access

   ..........................................   6

   

User management with Manager Fingerprints

   ....................................   6

   

Adding “Manager Add” and “Manager Delete” fingerprints

   ..................   6

   

Adding a Fingerprint or Keycard User

   ............................................................   6

   

Remove Fingerprint or Keycard Access

   ........................................................   6

   

Settings

   ................................................................................................................   6

   

Remove ALL Users

   ..................................................................................................   6

   

Setting Facility Code

   ..............................................................................................   6

   

Setting Lock Style and Door relay time

   ..........................................................   6

   

Setting “Door Open” Detection

   ..........................................................................   7

   

Setting Security Status

   ..........................................................................................   7

   

Setting Two Devices to be contacted

   .............................................................   7

   

Setting Alarm signal time

   .....................................................................................   7

   

User Operation

   ..................................................................................................   7

   

User to release door

   ...............................................................................................   7

   

Switch Alarm off

   .......................................................................................................   7

   

Advanced Application

   ....................................................................................   7

   

Working as a Slave Reader connecting to Controller

   ..............................   7

   

Working as a Slave Reader connecting to Controller Wiring Diagram

   ..   8

   

Working as Controller connecting to a Slave Reader

   ..............................   8

   

Working as Controller connecting to a Slave Reader Wiring Diagram

   ..   8

   

Using Two Access Controls On One Door

   ....................................................   8

   

Using Two Access Controls On One Door Wiring Diagram

   .........................   8

   

Two Devices Interconnected & Interlocking- Two Doors

   .......................   8

   

Two Devices Interconnected & Interlocking- Two Doors Wiring 
Diagram

   ....................................................................................................................................   9

   

 

 

 

Description 

The KAS-320-FP Fingerprint Access Control is perfect for home and/or office use, 
combining fingerprint access and keycard access in the one system. 
Program and delete individual cards and fingerprints, includes remote control for 
easy programing. 
 
 
 
 
 
  

Содержание KSS-320-FK

Страница 1: ...kas com au kas com au For orders enquiries and technical support please call 1300 939 669 tech kas com au www KAS com au User Guide KSS 320 FK Access Control...

Страница 2: ...ings 6 Remove ALL Users 6 Setting Facility Code 6 Setting Lock Style and Door relay time 6 Setting Door Open Detection 7 Setting Security Status 7 Setting Two Devices to be contacted 7 Setting Alarm s...

Страница 3: ...screws and 1 hole for the cable Fix the back cover firmly on the wall with 4 flathead screwsprovided Thread the cable through the cable hole Attach the device face to the back cover Sounds and Lighti...

Страница 4: ...ND Request to Exit Button Door Contact Black GND Negative Regulated Power Input Red 12V 12V DC Positive Regulated Power Input Brown D IN Door Contact Yellow OPEN Request to Exit Button Grey Alarm Alar...

Страница 5: ...Add Card over face of control 2 Enter 1st users fingerprint twice Note lift finger after first scan and place back on scanner for second scan or Scan new users Keycard 3 To add more users Repeat step...

Страница 6: ...ger Delete fingerprints 1 Enter programing mode 2 Press 1 1 3 Scan fingerprint twice This will be the ADD Fingerprint 4 Press 2 5 Scan another finger twice This will be the DELETE fingerprint 6 Press...

Страница 7: ...Select Status Press 7 0 Normal Status Press 7 1 Lock on Status Press 7 2 Alarm Status 3 Press Setting Two Devices to be contacted Disabled Factory default 1 Enter programming mode 2 Press 8 0 Disabled...

Страница 8: ...erified upon entering and exiting The information on the 2 devices is shared so users can enroll on either device gaining access on both sides of the door This doubles you current memory to 6000 users...

Страница 9: ...com au 4 Scan Keycard or fingerprint on second access control 5 Enter second door 6 Shut second door Two Devices Interconnected Interlocking Two Doors Wiring Diagram KAS 320 FP Controller 1 KAS 320 F...

Отзывы: