background image

   

kas.com.au 

kas.com.au 

5.

 

To add more users - Repeat steps 3 and 4 

6.

 

Press “ # ” to exit Programing mode 

   
   

   

   

   

Adding a Fingerprint/ Keycard user - Appointing specific ID number to 
user  

Fingerprint ID Numbers can be from 3 to 1000 
Keycard ID Numbers can be from 1001 to 3000 

1.

 

Enter programing mode 

2.

 

Press “ 1 ” 

3.

 

Enter User chosen ID number and press “ # ”  

4.

 

Scan fingerprint twice or Scan Keycard 

5.

 

To add more users - Repeat steps 3 and 4 

6.

 

Press “ # ” to exit Programing mode 

Removing Fingerprint or Keycard User Access 

1.

 

Enter programing mode 

2.

 

Press “ 2 ” 

3.

 

Enter fingerprint or Swipe card over control or Enter User ID No 

4.

 

To remove more users - Repeat steps 3 

5.

 

Press “ # ” exit programming mode  

 

User management with Manager Fingerprints 

Manager fingerprints must be added before using this method. 
Manager fingerprints must be added using the remote control method first. 
 

Adding “Manager Add” and “Manager Delete” fingerprints 

1.

 

Enter programing mode 

2.

 

Press “ 1 ” “ 1 ”   “ # ” 

3.

 

Scan fingerprint twice - This will be the “ADD Fingerprint” 

4.

 

Press “2 ” “ # “ 

5.

 

Scan another finger twice – This will be the “DELETE fingerprint” 

6.

 

Press “ * ” 

 

Adding a Fingerprint or Keycard User 

1.

 

Scan Manager ADD fingerprint 

2.

 

Scan new user fingerprint twice or Scan Keycard 

3.

 

Scan Manager ADD fingerprint 

 

Remove Fingerprint or Keycard Access 

1.

 

Scan Manager DELETE fingerprint 

2.

 

Scan fingerprint or Scan Keycard 

3.

 

To remove more users simply repeat step 2 

4.

 

Scan Manager DELETE fingerprint 

Settings 

Remove ALL Users 

This will delete all fingerprint and card users including manager fingerprints.  
Only Manager Cards will still be programmed  

1.

 

Enter programing mode on the remote control 

2.

 

Enter 20000 

3.

 

Press “ # ”  

Setting Faculity Code 

This operation might be required when the control is acting as a Wiegand reader 
and connected to multi-door controllers 

1.

 

Press “ 3 ”  

2.

 

0 to 255 

3.

 

Press “ # ” 

Setting Lock Style and Door relay time 

“Fail Safe” and “Fail Secure” are the setting your door will be in when there is no 
power to the strike. 

Содержание KSS-320-FK

Страница 1: ...kas com au kas com au For orders enquiries and technical support please call 1300 939 669 tech kas com au www KAS com au User Guide KSS 320 FK Access Control...

Страница 2: ...ings 6 Remove ALL Users 6 Setting Facility Code 6 Setting Lock Style and Door relay time 6 Setting Door Open Detection 7 Setting Security Status 7 Setting Two Devices to be contacted 7 Setting Alarm s...

Страница 3: ...screws and 1 hole for the cable Fix the back cover firmly on the wall with 4 flathead screwsprovided Thread the cable through the cable hole Attach the device face to the back cover Sounds and Lighti...

Страница 4: ...ND Request to Exit Button Door Contact Black GND Negative Regulated Power Input Red 12V 12V DC Positive Regulated Power Input Brown D IN Door Contact Yellow OPEN Request to Exit Button Grey Alarm Alar...

Страница 5: ...Add Card over face of control 2 Enter 1st users fingerprint twice Note lift finger after first scan and place back on scanner for second scan or Scan new users Keycard 3 To add more users Repeat step...

Страница 6: ...ger Delete fingerprints 1 Enter programing mode 2 Press 1 1 3 Scan fingerprint twice This will be the ADD Fingerprint 4 Press 2 5 Scan another finger twice This will be the DELETE fingerprint 6 Press...

Страница 7: ...Select Status Press 7 0 Normal Status Press 7 1 Lock on Status Press 7 2 Alarm Status 3 Press Setting Two Devices to be contacted Disabled Factory default 1 Enter programming mode 2 Press 8 0 Disabled...

Страница 8: ...erified upon entering and exiting The information on the 2 devices is shared so users can enroll on either device gaining access on both sides of the door This doubles you current memory to 6000 users...

Страница 9: ...com au 4 Scan Keycard or fingerprint on second access control 5 Enter second door 6 Shut second door Two Devices Interconnected Interlocking Two Doors Wiring Diagram KAS 320 FP Controller 1 KAS 320 F...

Отзывы: