Karel MS224 Installation & Maintenance Guide
Edition 3.2
28
MS224 CPUKON Card
PC
PC CM Socket
Pin No
Signal 25-pin
connector
Pin No
9-pin connector
Pin No
1 GND
7
5
2 TX
3
2
3 RX
2
3
4 - -
-
The signal names above are given with respect to MS224 system and these
pin assignments are valid only for IBM compatible devices. If your device is not
IBM compatible, then you must provide the requested pin connections to
match the signaling parameters of the system.
The communication protocol for PC - Exchange connection is illustrated in the
following table:
For PC
Data Bits
8
Stop Bit
1
Parity
None
Baud Rate
4800 Bps
The CM224 and PK224 modules are able to set the communication protocol to
the appropriate values, automatically.
•
D
ATA FORMAT OF
CM224 :
A call record consists of two lines, each followed by Carriage return (0Dh) and
Line Feed (0Ah) characters.
Structure of the first line:
Starting Character
Position
Field Width
Information
1
1
#; indicates start of record
2
4
4 digit counter value
6 1
Space
7
4 or 2
Call type
11 1
Space
12
1
Common Pool information
- Call type:
LDIS
Long Distance
INTL
International
IC
Incoming
Call type field and the preceding space are not sent to the PC for local calls.
- Common pool information field contains the character “C” for the calls made
from the common pool. If the call is not made from the common pool then
this field and the preceding space are not sent to the PC.
Содержание MS224
Страница 1: ...Karel MS224 T e l e p h o n e S y s t e m Installation Maintenance Guide Edition 3 2...
Страница 5: ......
Страница 23: ......
Страница 43: ......
Страница 47: ......
Страница 52: ...Karel MS224 Installation Maintenance Guide Edition 3 2 49 Figure B 4 Figure B 5...