- 40 -
C1453
00602.
fm
English
Information about failures
GB
R750
Output reduction
Clogged fuel filter
Replace filter (see “Fuel filter replace-
ment”)
Presence of air in the fuel supply circuit
Carry out bleeding (see “Fuel supply circuit
bleeding”)
Injection pump malfunction
Replace the pump
Apply to an authorised workshop
Dirty or faulty injectors
Replace the injectors
Apply to an authorised workshop
Clogged air filter
Clean or replace the filter
Engine overheating
Apply to an authorised workshop
Insufficient combustion air flow
Apply to an authorised workshop
The battery
warning light
comes on
The alternating current generator does
not charge the battery
Check and, if appropriate, replace the al-
ternating current generator
Apply to an authorised workshop
The oil pressure
warning light
comes on
Engine oil pressure too low
Apply to an authorised workshop
The warning
light which de-
tects water in
fuel comes on
Presence of water in the fuel filter
Replace filter (see “Fuel filter replace-
ment”)
The engine indi-
cator light (MIL)
comes on
Electronic engine management does not
work properly
Apply to an authorised workshop
Engine malfunction
Apply to an authorised workshop
Antiparticulate filter blockedo
Clean or replace the filter (see "Cleaning the
antiparticulate filter")
Problem
Cause
Remedy