Operation
Light and sound signals
The cleaning robot can emit light and sound signals to
indicate various operating states, critical situations and
fault codes.
An fault code table can be found in chapter:
Preparing the glass surface
1. Before using the cleaning robot, make sure that no
objects protrude into the movement space of the
cleaning robot, which could hinder its movement.
Illustration J
Obstacles can be, for example:
●
Curtains and drapes
●
Objects on windowsills
●
Window pictures and stickers
LED
Signal
Description, notes
LED battery status, when
charging
Flashes green
2 s on / 2 s off
●
Battery is being charged.
Lights up green
Indicator tone at the end of
the charging process
●
Battery fully charged, cleaning robot ready for use.
Flashes red
0.5 s on / 0.5 s off
●
Fault during charging.
(For remedies, see chapter:
)
LED device status, clean-
ing robot in the station
Flashes green
2 s on / 2 s off
●
The cleaning robot detergent container is being filled.
Lights up green
Indicator tone at the end of
the filling process
●
Detergent container completely filled.
Flashes red 1 s on / 3 s off
●
Tank empty.
(For remedies, see chapter:
)
LED battery status, in op-
eration
Lights up green
●
Battery fully charged, cleaning robot ready for use.
Lights up red
●
Battery almost discharged, place the cleaning robot in the
station to recharge after completion of the current clean-
ing process.
Flashes red
Warning tone every 10 s
●
Battery is discharged, remove the cleaning robot from the
glass surface immediately and place it in the station for
charging.
LED device status, when
attaching to a glass sur-
face
Flashes green
●
Cleaning robot suctions onto the glass surface.
Lights up green
●
Cleaning robot suctioned properly.
Flashes red
1 s on / 1 s off
●
Cleaning robot NOT suctioned properly, remove the
cleaning robot from the glass surface immediately. Clean
the suction cups and the main seal and check the main
seal for correct seating in the mount. Attach the cleaning
robot again.
LED device status, in oper-
ation
Lights up green
●
Cleaning robot active.
Flashes green
2 s on / 2 s off
Reminder tone every
5 min
●
Pause activated. Press the On / Off button to continue the
cleaning process.
Flashes red
Warning tone every 10 s
●
Battery is discharged, remove the cleaning robot from the
glass surface immediately and place it in the station for
charging.
Flashing green, right / left
alternating
Cleaning finished indicator
tone
●
Cleaning finished. Cleaning robot moves to its original po-
sition. Remove the cleaning robot from the glass surface.
Bluetooth
®
status LED
Off
●
No bluetooth
®
-Active connection.
Flashing blue
●
Waiting for confirmation: Briefly press the On / Off button.
Lights up blue
●
Bluetooth
®
-Active connection.