background image

     

7

Please observe the following warning notes 
when handling batteries:

Danger

Risk of explosion! Do not put tools or similar 
on the battery, i.e. on the terminal poles 
and cell connectors.

Danger

Risk of injury! Ensure that wounds never 
come into contact with lead. Always clean 
your hands after having worked with batter-
ies.

Danger

Risk of fire and explosion!

Smoking and naked flames are strictly 
prohibited. 

Rooms where batteries are charged 
must have good ventilation because 
highly explosive gas is emitted during 
charging. 

Batteries must not be stored outside.

DANGER

Danger of causticization!

Rinse thoroughly with lots of clear water 
if acid gets into the eye or comes in con-
tact with the skin.

Then consult a doctor immediately.

Wash off the acid If it comes in contact 
with the clothes.

Warning

Regularly check the fluid level in acid-filled 
batteries.

– The acid in a fully charged battery has a 

specific weight of 1.28 kg/l at a temper-
ature of 20 °C. 

– The acid in a partially discharged bat-

tery has a specific weight between 1.00 
and 1.28 kg/l. 

– The specific weight of the acid must be 

uniform in all cells.

Unscrew all cell caps.

Take a sample from each cell using the 
acid tester.

Put the acid sample back into the same 
cell. 

Where fluid level is too low, top up cells to 
the mark provided with distilled water.

Charge battery.

Screw in cell caps.

We recommend the use of our batteries 
and chargers; only then a claim under war-
ranty exists.

NOTICE

With the KM 105/100(110) R Bp pack the 
low-maintenance batteries and the charger 
are already installed.

ATTENTION

Only if you use the batteries and chargers 
recommended by Kärcher, a claim under 
warranty exists.

Note

When using batteries of other manufactur-
ers, the maximum battery dimensions must 
be observed.

The appliance requires 4 single batteries 
with 6 volt each. 
The available space (LxWxH) in the device 
is: 622 mm x 402 mm x 379 mm
Please follow these instructions if you are 
using low-maintenance batteries:
– It is necessary to conform to the maxi-

mum battery dimensions. 

– When charging low-maintenance bat-

teries, the left cover must be opened.

– While charging maintenance-free bat-

teries, follow the specifications of the 
battery manufacturer. 

Open left cover.

Remove the appliance cover.

Insert batteries into the battery mount.

Warning

Pay attention to correct poles.

Connect pole terminal (red cable) to 
positive pole (+).

Screw the connection lines onto the 
batteries.

Connect pole terminal to negative pole 
(-).

NOTICE

When removing the battery, make sure that 
the negative pole lead is disconnected first. 
Check that the battery pole and pole termi-
nals are adequately protected with pole 
grease.

NOTICE

Charge the batteries before commissioning 
the appliance.

DANGER

Risk of injury!

Comply with safety regulations on the 
handling of batteries. Observe the di-
rections provided by the manufacturer 
of the charger.

DANGER

Risk of injury!

Only put the charger into operation if 
the mains connection is free of damage. 
A damaged mains connection must im-
mediately be replaced by the manufac-
turer, the customer service or a quali-
fied person.

DANGER

Risk of injury!

Charge the battery only with an appro-
priate charger.

NOTICE

The charger is controlled electronically and 
completes the charging process automati-
cally. All functions of the device are auto-
matically interrupted during the charging 
process.

NOTICE

When the batteries are charged, first re-
move the charger from the mains and then 
disconnect it from the batteries.

With the KM 105/100(110) R Bp pack the 
low-maintenance batteries and the charger 
are already installed.

1 Retainers for mains connection (fold-

ing)

2 Mains cable with mains plug
3 Connection for mains connection of the 

charger

4 Batteries

Open left cover.

Fold in retainers and remove mains 
connection.

Insert the plug of the charger into the 
socket.

Notes regarding the battery

Safety notes regarding the batteries

Observe the directions on the 
battery, in the instructions for 
use and in the vehicle operating 
instructions!
Wear an eye shield!

Keep away children from acid 
and batteries!

Risk of explosion!

Fire, sparks, open light, and 
smoking not allowed!

Danger of causticization!

First aid!

Warning note!

Disposal!

Do not throw the battery in the 
dustbin!

Check and correct the fluid level of the 
battery (only for low-maintenance 
batteries)

Recommended batteries, chargers

Use of batteries and chargers of other 
manufacturers

Maximum battery dimensions (single 
battery)

Installing and connecting the batteries

Charging battery

(1) Charging process KM 105/100(110) R 
Bp Pack

1

2

3

1

4

11

EN

Содержание KM 105/100 R Bp

Страница 1: ...KM 105 100 R Bp KM 105 100 R Bp Pack KM 105 110 R Bp KM 105 110 R Bp Pack 59658630 11 14...

Страница 2: ...2...

Страница 3: ......

Страница 4: ...http www kaercher com dealersearch...

Страница 5: ...ine EN 1 Proper use EN 2 Foreseeable misuse EN 2 Suitable surfaces EN 2 Safety instructions EN 2 Safety instructions concern ing the operation EN 2 Operations EN 2 Safety information concern ing the d...

Страница 6: ...ing clothes Wear sturdy shoes and avoid wearing loose fitting clothes Check the immediate vicinity prior to starting e g children Ensure suffi cient visibility Never leave the device unattended as lon...

Страница 7: ...bris into the path of the roller brush The rotating roller brush 4 moves the dirt and debris directly into the waste container 5 The dust raised in the container is sep arated by the dust filter 2 and...

Страница 8: ...alled KM 105 100 110 R Bp not included in delivery Optional The following equipment that is installed when ordering ex work or can be subse quently installed is not displayed Beacon lamp Overhead guar...

Страница 9: ...e main switch being switched on and the key Intelligent Key inserted A OFF Device is switched off B ON The appliance is now ready for opera tion C Drive the machine Drive to the operating location in...

Страница 10: ...let you must create an unloading ramp us ing the boards provided To unload the machine proceed as follows Cut plastic packing belt and remove foil Remove the elastic tape fasteners at the stop points...

Страница 11: ...the battery manufacturer Open left cover Remove the appliance cover Insert batteries into the battery mount Warning Pay attention to correct poles Connect pole terminal red cable to positive pole Scre...

Страница 12: ...e intelligent key grey or yellow with the authorisation for the operation of the appliance must be inserted in the key slot of the control panel The main switch must be in position 1 The programme sel...

Страница 13: ...tly lift the waste container and swivel it downwards to the rear then unhinge the waste container Empty waste container Slide the waste container in and lock it in place check for proper seating of th...

Страница 14: ...appliances used for commercial purposes are subject to safety inspec tions according to VDE 0701 Use only roller brushes side brushes that are provided with the appliance or specified in the Operatio...

Страница 15: ...sed Unscrew all 3 star grip nuts at the bot tom of the side brush by hand For this purpose reach through the bristles of the side brush Remove the wiper blade Clip new side brushes on to driver and sc...

Страница 16: ...lacing the sealing strips unscrew the screws completley insert new seal ing strip fit retaining plate adjust seal ing strips and screw down retaining plate Side sealing strips Adjusting the sealing st...

Страница 17: ...for proper seating Inform K rcher Customer Service Dust gathers in the machine Insufficient vacuum performance Empty waste container Switch on suction blower Check dust filter clean or replace Check f...

Страница 18: ...en Is displayed high emptying system as soon as a sweeping programme has been selected and the waste container is not fully retracted and tipped inwards All sweeping functions are prevented Turn the p...

Страница 19: ...e battery is empty The operation of the device is prevented for the protec tion of the battery device can no longer be driven Charge battery 20 MF mod requests firmware update Appears if the machine c...

Страница 20: ...Volume of waste container KM 105 100 R low emptying system KM 105 110 R high emptying system l kg l kg 2 x 35 2 x 50 80 110 2 x 35 2 x 50 80 110 Maximum unloading height high emptying system mm 1550 1...

Страница 21: ...rake operated electrically with spring Filter and vacuum system Filter system TACT TACT Category of use filter for non hazardous dust M M Nominal vacuum suction system mbar 6 6 Nominal volume flow suc...

Страница 22: ...335 2 29 EN 60335 2 72 EN 61000 3 2 2006 A1 2009 A2 2009 EN 61000 3 3 2008 EN 61000 6 2 2005 EN 62233 2008 Applied conformity evaluation method 2000 14 EC Appendix V Sound power level dB A Measured Gu...