10
English
The machine produces dry ice pellets con-
sisting of liquid carbon dioxide. The size of
the dry ice pellets is selected via different
extruder plates.
The machine is only to be used in dry
rooms.
Do not spray the machine with water to
clean it. Wipe the machine housing using a
damp cloth.
The application may only be installed by
authorised technicians!
Liquid carbon dioxide streams into the cyl-
inder and hardens into dry ice snow by the
drop in pressure. This dry ice snow is com-
pacted by a hydraulic cylinder and pressed
through the extruder plate. This creates cy-
lindrical dry ice sticks, which breaks down
into pellets.
1 Key "On"
2 Indicator lamp "Oil temperature high"
3 Indicator lamp "Motor overload"
4 Indicator lamp "Cycle too long"
Refer to "Help with malfunctions/errors
with display".
5 Operating hour counter
6 Steam pressure manometer
7 Oil pressure manometer
8 Main switch
9 Emergency-stop button
10 Key "Reset"
Resets the automatic operation inter-
ruption following a malfunction.
11 Key "Off"
The piston stroke is terminated; the pis-
ton will move to the front position and
machine will stop.
12 Pellet ejector
13 Volume control PCS (option)
14 Key switch "Direct/PCS" (option)
15 Key "Start PCS" (option)
16 Rotary knob "Production time/volume
(option)
Danger
Risk of injury on account of electric shock.
Pull the plug out of the socket before open-
ing the control cabinet.
몇
Warning
Installation sets must only be installed by
authorized personnel.
Î
Fasten the housing of the volume con-
trol to the side of the appliance housing
with three screws.
Î
Install the cable screw connection ex-
haust into the boring on the appliance.
Î
Guide the volume control cable through
the cable screw connection.
Î
Remove the rear side of the housing.
Î
Guide the volume control cable through
an used cable screw connection into the
switch cabinet of the appliance.
Î
In the switch cabinet: Remove the jump-
er from terminals 5 to 7.
Î
Connect the volume control cable to the
terminals 5, 0 and 7 as per circuit dia-
gram.
Î
Reattach the rear side of the housing.
Danger
Risk of suffocation on account of carbon di-
oxide. The carbon dioxide content in the air
at the place where the machine is used will
increase when the machine is running. En-
sure adequate ventilation at the place of
use; if possible, use an alarm to warn per-
sons. Symptoms of high levels of carbon di-
oxide in the air that is breathed in:
–
3...5%: headache, faster breathing.
–
7...10%: headache, nausea and per-
haps even unconsciousness.
If any of these symptoms occur, please
switch off the machine immediately and get
a breath of fresh air and improve the venti-
lation before starting work again with the
machine.
Proper use
Function
Control elements
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
CO
2
16
Mounting the installation set
"Volume control PCS" (op-
tion)
Operation
Start up
Содержание IP 55
Страница 2: ......
Страница 47: ...47 5 0 7 3 5 7 10 79 C Direkt PCS Direkt n Off Direkt PCS PCS n PCS PCS Off On 0 ff 0 1 2 3 4 PCS...
Страница 48: ...48 1 V5 2 3 4 5 6 7 8 9 10 11 12 K rcher K rcher MIN MAX 45 C EV5 100...
Страница 99: ...cc 99 99 99 100 100 100 PCS 100 101 101 101 102 103 104 104 104 104 79 C EN 511 3 5 7 10...
Страница 101: ...cc 101 3 5 6 7 5 0 7 3 5 7 10 79 C PCS PCS PCS PCS PCS 0 0 1 2 3 4 PCS...
Страница 102: ...102 cc 1 EV5 2 3 4 5 6 7 8 9 10 11 12 K rcher K rcher MIN MAX 45 C EV5 100...
Страница 103: ...cc 103 40 C MIN MAX 1000 2000 M3 1 1 M4 2 5 M5 5 1 M6 8 8 M8 21 4 M10 44 M12 88 M14 119 M16 183 M20 224 Reset EV5 EV5...
Страница 107: ...107 3 5 7 10 79 C PCS PCS PCS PCS PCS 0 0 1 2 3 4 PCS...
Страница 108: ...108 1 EV5 2 3 4 5 6 7 8 9 10 11 12 K rcher K rcher M N MAX 45 C EV5 100...
Страница 109: ...109 40 C M N MAX 1000 2000 M3 1 1 M4 2 5 M5 5 1 M6 8 8 M8 21 4 M10 44 M12 88 M14 119 M16 183 M20 224 Reset EV5 EV5...
Страница 117: ......