background image

     

7

Î

Connect the water supply hose to the 
respective water inlet (arrow).

Î

Open the lock on the appliance cover 
and swivel the appliance cover up-
wards.

Î

Swivel the latch of the appliance hood 
upwards to keep it from shutting inad-
vertently.

Î

Check the water filter for contamination, 
clean/replace if required.

Î

Check the position of the ball tap in the 
antifreeze/water tank, set to the water 
tank on the right.

Î

Close the drain tap of the water tank.

Î

Switch on the battery main switch.

Î

Tilt the safety latch of the appliance 
hood toward the bottom.

Î

Tilt the appliance hood downward and 
lock it.

Î

Open the door to the operating panel 
and switch on the ignition via the keys-
witch.

If the tank level is low, the water will be sup-
plied

Note

The appliance can only be operated with 
the appliance hood closed. The appliance 
will switch off when the appliance hood is 
opened.

Î

Release emergency-stop button by 
turning.

Î

Open the operating panel door.

Î

Turn the key switch to the right.

The control voltage is switch on and the dis-
play shows the operating status.

At low ambient temperatures, the preheat-
ing process will start automatically. The re-
spective message is shown on the display.

Î

Press the F2 key to start the motor.
Motor runs warm.

During the warm up time, the display will 
show the clock symbol.

After the warm up time, the appliance will 
be ready for high pressure operation.

Î

Connect the high pressure hose, gun 
and the spray pipe without nozzle as 
described in chapter "Startup".

Î

Activate the gun about 30 to 40 sec-
onds until a continuous water jet is emit-
ted from the spray pipe.

Î

Switch off the motor.

Î

Install the nozzle as described in the 
chapter "Connecting the nozzle".

Note

The water pressure can be changed right 
after startup with the key switch as well as 
during operation.

Î

Adjust the water pressure using the F5 
and F4 keys "Increase/reduce water 
pressure".
The water pressure can be changed in 
increments of 5 MPa (50 bar).

The set water pressure has been reached.

Î

Step 1: Press F6 key.

Î

Step 2: Press F4 key.

Start the engine

Ventilating the high pressure system

+

-

8

7

Settings

Adjust the water pressure

Adjust the brightness and contrast of 
the display

+

-

8

7

MENUE

9

EN

Содержание HD 7/250 DE TR1

Страница 1: ...HD 7 250 De Tr1 59633200 08 10...

Страница 2: ...2...

Страница 3: ...g on a scaffold so that the person does not fall from the scaffold due to the recoil force generated by the appliance For manual work with a spray gun the nozzle diameter must be selected so that the...

Страница 4: ...ral oil con taining wastewater into the soil surface waters or sewer sys tems Notes about the ingredients REACH You will find current information about the ingredients at http www karcher de de untern...

Страница 5: ...ation plates 27 Storage compartment 28 Hinge storage compartment 29 Emergency stop button 30 Switch box 31 Operating field 32 Vice 33 Socket control line 34 Exterior air connection supply 35 Water inl...

Страница 6: ...rating panel 8 7 Symbols on the display Symbol Meaning Nominal pressure Actual pressure Motor oil pressure Fuel level Water level in tank Cool water temperature Reset Motor ON Motor OFF Reduce nominal...

Страница 7: ...from the ve hicle lighting and insert it into the plug storage on the drawbar Secure the machine with wheel chocks to prevent it from rolling away Disconnect the towing vehicle Align the appliance hor...

Страница 8: ...even if they are in good condition High pressure hoses that have been stored for more than 2 years may no longer be used Store the high pressure hose so that there is no mechanical strain Store in a c...

Страница 9: ...oltage is switch on and the dis play shows the operating status At low ambient temperatures the preheat ing process will start automatically The re spective message is shown on the display Press the F...

Страница 10: ...re spray release the lever of the hand spray gun and let the release lock Press F3 key Depending on the load the motor should somewhat longer to cool off The display will show the trailing time of the...

Страница 11: ...olant circuit of the motor for sufficient antifreeze refill antifreeze as needed See Maintenance Procedures Check and refill the coolant If the appliance is not used for an ex tended period and if the...

Страница 12: ...sure can pene trate the skin and cause severe injuries and infections Stay away from leaks and do not search for leaks by hand Do not use flammable detergents to clean the appliance After completing t...

Страница 13: ...13 Pressure container 14 Compressed air filter 15 Pressure switch 16 2 2 way PN bypass valve 17 5 2 way valve 18 3 2 way valve 19 Burst disc safety 20 High pressure sensor 21 High pressure pump 22 Int...

Страница 14: ...nance Procedures Customer Service Replace oil filter insert on motor Customer Service Check the screw connections on the motor Call customer service if necessary Customer Service Once after the first...

Страница 15: ...ar acid resistant goggles gloves and an apron when working with battery acid Never charge the battery in the vicinity of open flames or igniting sparks The battery may only be charged in rooms that ar...

Страница 16: ...aminated Clean the radiator Operator V belt tension on the ventilator too low Retension V belt Customer Service Thermostat defective Replace the thermostat Customer Service Cable breakage Replace the...

Страница 17: ...ressure below 0 15 MPa 1 5 bar Water reservoir empty Filling the Water Reservoir Operator Water filter contaminated Clean water filter Operator Backflow valve on the advance pump contami nated Check b...

Страница 18: ...sing standard nozzle MPa bar 250 2500 Max excess operating pressure safety valve MPa bar 300 3000 Drive motor performance kW 74 Motor rpm 1 min 3000 Battery V Ah 12 55 Nozzle size 0 6 Max recoil force...

Страница 19: ...purchase We hereby declare that the machine de scribed below complies with the relevant basic safety and health requirements of the EU Directives both in its basic design and construction as well as i...

Страница 20: ...Biatorbagy 36 23 530 64 0 www kaercher hu I K rcher S p A Via A Vespucci 19 21013 Gallarate VA 39 848 998877 www karcher it IE K rcher Limited Ireland 12 Willow Business Park Nangor Road Dublin 12 01...

Отзывы: