background image

     - 

14

Danger

This can lead to severe injuries and possi-
bly death. An improper startup and repair of 
the appliance and the spray unit is danger-
ous. 

Faults detected by the control are shown 
on the display.

1 Display
2 Fault indication
3 Reset key to confirm the fault

Î

Read the fault message on the display 
and remediate the fault as per the table 
below.

Î

Press the reset button to acknowledge/
confirm the fault message.

Faults

Faults with display

Display/meaning

Cause

Remedy

By whom

>Malfunction<
EMERGENCY 
STOP

Emergency Stop switch depressed

Unlock Emergency Stop switch

Operator

Remote control not connected

Create connection

Operator

Plug wet

Dry the plug

Operator

Plug defective

Replace the plug

Customer Service

Switch in the hand spray gun defective

Check the switch, replace

Customer Service

Cable breakage

Replace the cable

Customer Service

>Malfunction<
Hood open

Device hood open

Close appliance hood

Operator

Cable breakage

Replace the cable

Customer Service

Safety switch for appliance hood defective

Check safety switches.

Customer Service

>Malfunction<
Tank level

Fuel tank empty.

Refill diesel fuel

Operator

Level sensor defective

Replace level sensor

Customer Service

Cable breakage

Replace the cable

Customer Service

>Malfunction<
Cooling water level

See motor operating instructions
Level of coolant too low

Refill cooling water 

Operator

Radiator contaminated

Clean the radiator

Operator

V-belt tension on the ventilator too low

Retension V-belt

Customer Service

Thermostat defective

Replace the thermostat

Customer Service

Cable breakage

Replace the cable

Customer Service

>Malfunction<
Motor oil pressure

Motor oil level too low

Check the motor oil level

Operator

Oil the motor has the wrong viscosity

Replace engine oil.

Customer Service

Oil pressure switch on motor defective

Replace oil pressure switch on motor

Customer Service

Cable breakage

Replace the cable

Customer Service

Look for more instructions in the motor's operating instructions

>Malfunction<
Motor temperature

Coolant level in the motor too low

Check coolant units

Operator

Radiator contaminated

Clean the radiator

Operator

V-belt tension on the ventilator drive too low

Check V-belt tension

Operator

Tighten V-Belt

Customer Service

Thermostat defective

Check thermostat

Customer Service

Defective temperature switch

Check the temperature switch

Customer Service

Cable breakage

Replace the cable

Customer Service

Look for more instructions in the motor's operating instructions

>Malfunction<
Tyre pressure

Ball tap of drain open

Close the ball tap

Operator

Water in the compressed air tank

Drain water

Operator

Air system leaks

Seal the air system

Customer Service

Compressor defective

Repair the compressor

Customer Service

V-belt tension on the compressor drive too low Tighten V-Belt

Customer Service

Pressure switch is defective

Check/replace the pressure switch

Customer Service

Cable breakage

Replace the cable

Customer Service

16

EN

Содержание HD 7/250 DE TR1

Страница 1: ...HD 7 250 De Tr1 59633200 08 10...

Страница 2: ...2...

Страница 3: ...g on a scaffold so that the person does not fall from the scaffold due to the recoil force generated by the appliance For manual work with a spray gun the nozzle diameter must be selected so that the...

Страница 4: ...ral oil con taining wastewater into the soil surface waters or sewer sys tems Notes about the ingredients REACH You will find current information about the ingredients at http www karcher de de untern...

Страница 5: ...ation plates 27 Storage compartment 28 Hinge storage compartment 29 Emergency stop button 30 Switch box 31 Operating field 32 Vice 33 Socket control line 34 Exterior air connection supply 35 Water inl...

Страница 6: ...rating panel 8 7 Symbols on the display Symbol Meaning Nominal pressure Actual pressure Motor oil pressure Fuel level Water level in tank Cool water temperature Reset Motor ON Motor OFF Reduce nominal...

Страница 7: ...from the ve hicle lighting and insert it into the plug storage on the drawbar Secure the machine with wheel chocks to prevent it from rolling away Disconnect the towing vehicle Align the appliance hor...

Страница 8: ...even if they are in good condition High pressure hoses that have been stored for more than 2 years may no longer be used Store the high pressure hose so that there is no mechanical strain Store in a c...

Страница 9: ...oltage is switch on and the dis play shows the operating status At low ambient temperatures the preheat ing process will start automatically The re spective message is shown on the display Press the F...

Страница 10: ...re spray release the lever of the hand spray gun and let the release lock Press F3 key Depending on the load the motor should somewhat longer to cool off The display will show the trailing time of the...

Страница 11: ...olant circuit of the motor for sufficient antifreeze refill antifreeze as needed See Maintenance Procedures Check and refill the coolant If the appliance is not used for an ex tended period and if the...

Страница 12: ...sure can pene trate the skin and cause severe injuries and infections Stay away from leaks and do not search for leaks by hand Do not use flammable detergents to clean the appliance After completing t...

Страница 13: ...13 Pressure container 14 Compressed air filter 15 Pressure switch 16 2 2 way PN bypass valve 17 5 2 way valve 18 3 2 way valve 19 Burst disc safety 20 High pressure sensor 21 High pressure pump 22 Int...

Страница 14: ...nance Procedures Customer Service Replace oil filter insert on motor Customer Service Check the screw connections on the motor Call customer service if necessary Customer Service Once after the first...

Страница 15: ...ar acid resistant goggles gloves and an apron when working with battery acid Never charge the battery in the vicinity of open flames or igniting sparks The battery may only be charged in rooms that ar...

Страница 16: ...aminated Clean the radiator Operator V belt tension on the ventilator too low Retension V belt Customer Service Thermostat defective Replace the thermostat Customer Service Cable breakage Replace the...

Страница 17: ...ressure below 0 15 MPa 1 5 bar Water reservoir empty Filling the Water Reservoir Operator Water filter contaminated Clean water filter Operator Backflow valve on the advance pump contami nated Check b...

Страница 18: ...sing standard nozzle MPa bar 250 2500 Max excess operating pressure safety valve MPa bar 300 3000 Drive motor performance kW 74 Motor rpm 1 min 3000 Battery V Ah 12 55 Nozzle size 0 6 Max recoil force...

Страница 19: ...purchase We hereby declare that the machine de scribed below complies with the relevant basic safety and health requirements of the EU Directives both in its basic design and construction as well as i...

Страница 20: ...Biatorbagy 36 23 530 64 0 www kaercher hu I K rcher S p A Via A Vespucci 19 21013 Gallarate VA 39 848 998877 www karcher it IE K rcher Limited Ireland 12 Willow Business Park Nangor Road Dublin 12 01...

Отзывы: