14
Danger
This can lead to severe injuries and possi-
bly death. An improper startup and repair of
the appliance and the spray unit is danger-
ous.
Faults detected by the control are shown
on the display.
1 Display
2 Fault indication
3 Reset key to confirm the fault
Î
Read the fault message on the display
and remediate the fault as per the table
below.
Î
Press the reset button to acknowledge/
confirm the fault message.
Faults
Faults with display
Display/meaning
Cause
Remedy
By whom
>Malfunction<
EMERGENCY
STOP
Emergency Stop switch depressed
Unlock Emergency Stop switch
Operator
Remote control not connected
Create connection
Operator
Plug wet
Dry the plug
Operator
Plug defective
Replace the plug
Customer Service
Switch in the hand spray gun defective
Check the switch, replace
Customer Service
Cable breakage
Replace the cable
Customer Service
>Malfunction<
Hood open
Device hood open
Close appliance hood
Operator
Cable breakage
Replace the cable
Customer Service
Safety switch for appliance hood defective
Check safety switches.
Customer Service
>Malfunction<
Tank level
Fuel tank empty.
Refill diesel fuel
Operator
Level sensor defective
Replace level sensor
Customer Service
Cable breakage
Replace the cable
Customer Service
>Malfunction<
Cooling water level
See motor operating instructions
Level of coolant too low
Refill cooling water
Operator
Radiator contaminated
Clean the radiator
Operator
V-belt tension on the ventilator too low
Retension V-belt
Customer Service
Thermostat defective
Replace the thermostat
Customer Service
Cable breakage
Replace the cable
Customer Service
>Malfunction<
Motor oil pressure
Motor oil level too low
Check the motor oil level
Operator
Oil the motor has the wrong viscosity
Replace engine oil.
Customer Service
Oil pressure switch on motor defective
Replace oil pressure switch on motor
Customer Service
Cable breakage
Replace the cable
Customer Service
Look for more instructions in the motor's operating instructions
>Malfunction<
Motor temperature
Coolant level in the motor too low
Check coolant units
Operator
Radiator contaminated
Clean the radiator
Operator
V-belt tension on the ventilator drive too low
Check V-belt tension
Operator
Tighten V-Belt
Customer Service
Thermostat defective
Check thermostat
Customer Service
Defective temperature switch
Check the temperature switch
Customer Service
Cable breakage
Replace the cable
Customer Service
Look for more instructions in the motor's operating instructions
>Malfunction<
Tyre pressure
Ball tap of drain open
Close the ball tap
Operator
Water in the compressed air tank
Drain water
Operator
Air system leaks
Seal the air system
Customer Service
Compressor defective
Repair the compressor
Customer Service
V-belt tension on the compressor drive too low Tighten V-Belt
Customer Service
Pressure switch is defective
Check/replace the pressure switch
Customer Service
Cable breakage
Replace the cable
Customer Service
16