BR/BD 75/140 R, BR/BD 90/140 R
Basic Settings and Service Procedures
Page 41 / 71
New Unit Information 03.2004
Access setup menu
If the machine is switched on, the setup menu
can only be accessible if the unit is at a standstill.
Travel and/ or cleaning modes cannot be started
until the setup menu has been aborted.
The operator can use the setup menu to change
the basic settings. The information given in brak-
kets ( ) relate to the “control panel” diagram on
page 13.
1. Turn key switch (18) to position “I”. Wait until
the basic setting appears on the display.
2. Press the “INFO” (19) push-button and for-
ward drive (13) push-button at the same time
and keep them pressed until “end use back” or
“settings - end with jolt” appears on the display
(23).
3. Release both push-buttons again.
Select menu
Use the “increase water flow” (24) push-button
to scroll forwards in the menu. Press the “reduce
water flow” (20) push-button to scroll reverse in
the menu.
Setup menu
Change settings
Press the “Increase brush pressure” (8) push-
button to increase the settings.
Press the “Reduce brush pressure” (11) push-
button to reduce the settings.
Save settings
Press the “reverse drive” (17) push-button to save
the settings. The display then automatically
switches back to operating mode. If the unit is
switched off using the key switch before the push-
button “reverse drive” (17) has been pressed,
the settings will not be saved. When switched
back on, the unit then changes back to the origi-
nal basic settings.
The adjustments made become effective after
leaving the setup menu.
Deep-discharge protection
The deep-discharge protection is set to 18.0 Volt
in the factory. It cannot be changed. If the battery
voltage drops to the level of the deep-discharge
protection, all the functions are completely swit-
ched off.
REVISED