BR/BD 75/140 R, BR/BD 90/140 R
Basic Settings and Service Procedures
Page 39 / 71
New Unit Information 03.2004
Test mode
Information which can be displayed by consecutively pressing the “Memo” button (12)
REVISED
Display:
Meaning:
battery voltage
xx.xV
Battery voltage [resolution: 0.1V]
I_traction: xxA
Drive motor current [resolution: 1A]
I_brush: xxA
Brush motor current [resolution: 1A]
I_vacuum: xxA
Suction motor current [resolution: 1A]
I_squeegee:
x.xA
Suction bar lifting motor current [resolution: 0.1A]
I_brushhead:
x.xA
Brush head lifting motor current [resolution: 0.1A]
I_brake: x.xA
Magnet brake current [resolution: 0.1A]
tap_voltage:x.xV
Control voltage of the water metering valve [resolution: 0.1V]
brushhead switch
upper:x lower:x
X = 0: Limit switch of brush head lifting motor not actuated
X = 1: Limit switch of brush head lifting motor limit actuated
squeegee switch
upper:x lower:x
X = 0: Limit switch of suction bar lifting motor not actuated
X = 1: Limit switch of suction bar lifting motor actuated
seat switch: x
X = 0: Seat contact switch open (with time delay)
X = 1: Seat contact switch closed (with time delay)
accelerator x.xV
Output voltage of the drive sensor (suitable for mechanical
adjustment)