Unit functions 

Driving operation (battery-powere d unit) 

When the drive lever is pushed forward or backward, the unit moves in the corresponding directions. 
The drive lever also controls the driving speed. 
Braking of the machine is effected by releasing the drive lever (centre-position). If the unit is to be 
parked, the parking brake must be set and firmly engaged in the ratchet stop position. 

 

CAUTION:

 While engaged in driving operation, do not switch off the unit by means of the key 

switch. Instead, first release the drive lever, allow the machine to come to a standstill, and only then 
turn the key switch to the off position. The emergency-stop pushbutton should be activated only in 
emergency situations. 

 

Driving operation (mains-powered unit) 

The mains-powered unit is not equipped with an electric motor for driving operation. Due to the 
reduced unit weight resulting from the absence of the storage batteries used in the battery-powered 
unit version, the propulsive force of the brush rollers and/or disc brushes is sufficient to effect forward 
motion. The unit is not equipped with a parking brake. 

 

Cleaning operation 

When the cleaning head is lowered by means of the foot pedal, a microswitch automatically activates 
the brush rollers and/or disc brushes. Upon raising the cleaning head they are disabled again  in the 
same fashion. The brush contact pressure can be manually adjusted in four steps by means of a 
lever. If a brush overload is detected, the electronic control module automatically shuts off the brush 
motors, and the corresponding indicator light on the instrument panel illuminates. If this condition 
occurs, use the key switch to switch off the machine, raise the cleaning head and remove the cause 
of the overload (i.e., excessive brush contact pressure or entangled twine), and then switch on the 
machine again. On the BR 550 unit the brushes can be offset from each other in a parallel fashion in 
order to increase the width of the cleaning area from 550 mm to 700 mm. To make this adjustment, 
the clamping screw on the cleaning head must be loosened slightly.

 

 

Water supply 

The water supply control knob on the instrument panel is used to switch on the water pump while 
selecting the water feed volume for the cleaning head. When not using the unit turn the water metering 
valve to the zero position. This shuts off the water flow to the cleaning head. 

 

Vacuuming operation 

When the suction bar is lowered by means of the control lever, a microswitch automatically activates 
the suction turbine. Upon lifting the suction bar off the floor, the suction turbine will continue to run for a 
timed interval of 10 seconds in order to transport the remaining water volume still in the suction hose 
into the dirty-water tank. When the dirty-water tank reaches its full level, a float switch switches off the 
suction turbine, and a corresponding indicator light on the instrument panel illuminates. Using the 
override function of a sealed pushbutton on the instrument panel, the suction turbine can be switched 
on or off independently. The skew of the suction bar deviating from the axis of travel, as well as its 
incline can be adjusted according to the floor covering being cleaned. For the purpose of travel in the 
reverse direction, the suction bar must be raised. 

Содержание BR 550 BAT

Страница 1: ...ation Service Information International No 90 95 dated 18 Dec 1995 _________________________________________________________________________________________________ International Service Information P...

Страница 2: ...e batteries 8 Charging unit with programming abilities 8 Charging procedure 8 Modification from BR to BD unit version 8 Control element BR BD 500 battery powered unit 9 13 Complete printed circuit boa...

Страница 3: ...on Service Information International No 90 95 dated 18 Dec 1995 _________________________________________________________________________________________________ International Service Information Page...

Страница 4: ...Suction bar microswitch 3 Cleaning head 4 Drive wheel 5 Contact pressure of cleaning head 6 Cleaning head microswitch 7 Raise lower cleaning head 8 Suction bar 9 Dirty water suction hose 10 Parking b...

Страница 5: ...Raise lower suction bar lever 7 Water pump with filter 8 Suction turbine 9 Cleaning head contact pressure lever 10 Dirty water suction hose 11 L h foot pedal parking brake battery powered unit 12 R h...

Страница 6: ...8 9 10 1 Master switch mains powered unit only 2 Emergency stop switch battery powered unit only 3 Key switch battery powered unit only 4 Water supply control knob and water pump on off switch 5 Sucti...

Страница 7: ...ce Information Page 7 33 Unit functions Schematic diagram 1 Suction bar 2 Dirty water suction hose 3 Suction turbine 4 Hose coupling 5 Water control valve 6 Fresh water membrane bag 7 Fresh water stor...

Страница 8: ...lever If a brush overload is detected the electronic control module automatically shuts off the brush motors and the corresponding indicator light on the instrument panel illuminates If this conditio...

Страница 9: ...ne are automatically switched off However it is still possible to drive the unit to the nearest charging station Charging unit with programming abilities These units can be ordered either with or with...

Страница 10: ..._________________________________________ International Service Information Page 10 33 Control element BR BD 550 battery powered unit Complete printed circuit board 1 Fuses 2 Control module A2 3 Drive...

Страница 11: ...al Service Information Page 11 33 Control element BR BD 550 battery powered unit Drive control circuit board A1 Control module A2 1 Control module A2 2 Battery type microswitch 3 Drive control circuit...

Страница 12: ...___________________________________________________________________________________________ International Service Information Page 12 33 Control element BR BD 550 battery powered unit Fuses F1 Control...

Страница 13: ...nternational No 90 95 dated 18 Dec 1995 _________________________________________________________________________________________________ International Service Information Page 13 33 Control element B...

Страница 14: ...ct Information Service Information International No 90 95 dated 18 Dec 1995 _________________________________________________________________________________________________ International Service Info...

Страница 15: ...mp D4 LED rt Battery charge min S8 Microswitch Dirty water tank D5 LED rt Boot brake S9 Microswitch Suction bar D6 LED rt Brush overload S10 Microswitch Cleaning head D7 LED rt Dirty water tank full S...

Страница 16: ...______________________________________________ International Service Information Page 16 33 Control element BR BD 550 mains powered unit Complete printed circuit board 1 Control module A2 2 Terminal s...

Страница 17: ...___________________________________________________________________ International Service Information Page 17 33 Control element BR BD 550 mains powered unit Control module A2 1 Unit type microswitch...

Страница 18: ...________________________________________________________________________________________ International Service Information Page 18 33 Control element BR BD 550 mains powered unit Fuses F1 Transformer...

Страница 19: ...International No 90 95 dated 18 Dec 1995 _________________________________________________________________________________________________ International Service Information Page 19 33 Control element...

Страница 20: ...urbine on F1 Fuse Transformer primary F2 Fuse Control module F3 Fuse Water pump F4 Fuse Brush motor 1 disc motor F5 Fuse Brush motor 2 F6 Fuse Suction turbine K1 Solenoid Brush motors K2 Solenoid Suct...

Страница 21: ...he position 2 Unit does not move Emergency stop pushbutton was pressed Release emergency stop pushbutton Parking brake has been set indicator light flashes Release parking brake Batteries are discharg...

Страница 22: ...meter R1 Check rotary potentiometer and or adjust setting Replace if required Defective drive control module A1 Replace drive control module Main motor does not receive power Check connecting cables D...

Страница 23: ...tch and or adjust setting Replace if required Ensure proper connection Defective drive belt BR 550 or angle transmission BD 550 Replace drive belt angle transmission Solenoid K3 does not activate Chec...

Страница 24: ...n suction bar S9 Check microswitch Replace if required Defective solenoid K2 Check solenoid Replace if required Suction turbine without power Check connecting cables Defective suction turbine M3 Check...

Страница 25: ...nts based on intended application Wrong contact pressure Increase contact pressure see item 4 above No or too little water supply See item 6 above Poor water pick up See item 8 above Brush runs rough...

Страница 26: ..._______________________________ International Service Information Page 26 33 Troubleshooting BR BD 550 battery powered unit Problem Cause Remedy 15 When using the parking brake the indicator light doe...

Страница 27: ...l module F3 Water pump fuse Short circuit Clear electrical fault condition Blocked or defective pump Remove blockage Replace pump if required F5 F6 Fuses for brush disc motor Short circuit Clear elect...

Страница 28: ...or adjust setting Replace if required Ensure proper connection Defective drive belt BR 550 or angle transmission BD 550 Replace drive belt angle transmission Solenoid K1 does not activate Check soleno...

Страница 29: ...suction bar S5 Check microswitch Replace if required Defective solenoid K2 Check solenoid Replace if required Suction turbine without power Check connecting cables Defective suction turbine M4 Check...

Страница 30: ...d front blades if required consider the intended cleaning application and ensure that replacement squeegee blades are properly aligned Worn out or unsuitable brushes Replace brushes select brushes acc...

Страница 31: ...n Blocked or defective pump Remove blockage Replace pump if required F4 F5 Fuses for brush disc motors Short circuit Clear electrical fault condition Defective or overloaded brush motors without red L...

Страница 32: ...ar Brush Roller Disc Brush Diameter 105 mm 550 mm Rotation speed at idle 1 500 RPM 160 RPM Dimensions and Weights Working width adjustable 550 700 mm 550 mm Tank volumes fresh water dirty water 55 55...

Страница 33: ...Brush motor disc motor 2 x 800 W 800 W Water pump 100 W 100 W Vacuum Operatin Air volume 38 L sec 38 L sec Vacuum 170 mbar 170 mbar Brush Roller Disc Brush Diameter 105 mm 550 mm Rotation speed at idl...

Отзывы: