84
English
5.906-269.0 Rev. 00 (03/11)
Remove rear appliance cover.
Turn the programme selector switch to position 4
"Vacuuming".
Measure the voltage on the control PCB between
terminal strips X15 and X13.
Target value:
Whisper mode
–
15.0 +/- 0.2 Volt
Power mode
–
Battery voltage
Installation in reverse order
Remove rear appliance cover.
Plug in the main plug.
Measure the voltage on the control PCB between
terminal strips X16 and X12.
Target value:
–
27.0 +/- 0.2 Volt
Installation in reverse order
9.4.12Check supply voltage of the suction turbine
9.4.13Check the charge voltage