29
Maintenance
Solution Pump Replacement
Only qualified maintenance personnel are to perform
the following repairs.
Seul le personnel d'entretien qualifié peut effectuer des
réparations.
1. Turn off all switches and unplug the machine.
2. Remove recovery tank.
3. Remove the (2) screws that fasten the solution
tank to the frame, and tilt tank back to expose the
inside of the frame.
4. Remove solution hoses from fittings in pump.
5. Remove the (2) screws that fasten the pump to the
frame.
6. Reverse process to install pump.
8.645-740.0 Manual Operator - Admiral X/Admiral XL
Содержание Admiral X
Страница 11: ...11 Notes 8 645 740 0 Manual Operator Admiral X Admiral XL...
Страница 32: ...32...