30
Maintenance
Troubleshooting
PROBLEM
CAUSE
SOLUTION
No Power, Nothing
Runs
Is the cord plugged in.
Plug in cord.
Circuit breaker tripped in building.
Reset breaker.
Faulty switch.
Call for service.
Faulty power cord or pigtail.
Call for service.
Vacuum Motor Will
Not Run.
Vacuum circuit breaker tripped.
Reset breaker.
Faulty main vacuum switch.
Call for service.
Loose wiring.
Call for service.
Faulty vac motor.
Call for service.
Vacuum Motor Runs
But Suction Is Poor
Debris lodged in vac shoe.
Remove debris from vac shoe.
Dome gasket defective or missing.
Replace as necessary.
Vacuum hose cracked or hose cuff loose.
Replace or repair as necessary.
Recovery tank full / float ball stuck in the up
position.
Turn off vac motor. Drain and rinse recovery
tank.
Poor Or No Water
Flow (Carpet Is
Streaky)
Main pump switch off.
Turn on.
Jets clogged or missing.
Clean using a vinegar /water solution or
replace.
Solution filter clogged.
Drain solution tank and clean solution filter.
Faulty solenoid.
Call for service.
Brush Does Not
Spin
Brush switch off.
Turn on brush switch.
Brush circuit breaker tripped.
Reset circuit breaker.
Brush belt broken.
Replace as necessary.
Faulty brush motor.
Call for service.
8.645-740.0 Manual Operator - Admiral X/Admiral XL