MATTRESS SYSTEM SET-UP 

 

 

Note

: Make sure that the hose end of the mattress is towards the foot of the bed. 

         

Note

: When installing the KAP Medical mattress system, do not exceed the manufacturers rated weight of the   

 

mattress or the bed frame. See the bed manufacturer’s manual for bed frame weight rating. 

  

Note

: Make sure the CPR valve is in closed position, bolsters and air pad plugs are connected and locked in place 

before inflating the mattress 

          

Note:

 Care should be taken such that the air inlet vent on the control unit is not covered, and the control unit is  

 

not placed on the floor in such a manner that it is a hazard for flow of traffic or lowering of bed frame. 

Note:

  Before using the KAP Mattress System, please remove current mattress, mattress replacement systems or 

overlay systems from the bed. 

 

Overlay Mattress system

 

:  

 

When using the Overlay mattress system, care should be taken such that the overlay is placed directly on an 
existing 3” to 5” foam mattress. 

 

 

Unroll the Overlay and place it on the foam mattress.  

 

 

There are two elastic straps, one at the head and the other at the foot section.  Two long straps on one side and two 
short straps with buckles on the other side of the overlay.   Insert head and foot elastic straps around the foam 
mattress.  Loop each long side strap around the foam mattress and fasten it securely to the short strap on the other 
side using the buckle. 
 

Replacement Mattress system

 

:  

 

When using the replacement mattress system, care should be taken such that the mattress is placed directly on the 
bed frame. 

{Figure 1,(B), Page 16}

 

 

 

Unroll the Replacement Mattress and place it on the bed frame (BF).  

 

 

There are ten nylon black straps with buckles (F), two straps at the head of the mattress, two on the foot of the 
mattress, and three on each side of the mattress.  Loop each strap around the bed deck and secure using the 
buckle (D-ring). Note: Make sure Head, Knee and Foot sections of the bed can be raised and that straps are 
secured to the deck and not to the frame. Once the mattress is strapped, tuck the exposed straps under the 
mattress. 

 

 

Pull out the hanger on the back of the control unit (A) and suspend the control unit from the footboard (FB) of the 
bed (BF).  If the bed you are using does not have a footboard, place the control unit (A) on its base (not on its back 
where the filter is located) on a flat surface in front of the bed near the foot of the bed frame (BF).  

 

 

Uncoil the power cord (Q) and plug the cord into the appropriate AC power source (X), which is properly grounded.  
Plug the other end of the power cord into the control unit and press it in place. 

 

Note:  

Care should be taken such that the power cord of the control unit is not pinched, or has any objects placed 

on it.  Ensure it is not located where it can be stepped on or tripped over. Make sure the control units power inlet 
connection is positioned to easily disconnect the power cord from the unit. 

 

Connect the mating connector (R) on the mattress hose assembly (V) into the insert on the control unit connector 
and lock it in place.   

  

 

Note: 

Care should be taken such that the mattress hose is freely suspended without being pinched or kinked. 

 

Содержание K-1 Series

Страница 1: ...SYSTEM K 2 ELITE KARE ZONE DIGITAL ALTERNATING PRESSURE WITH ON DEMAND LOW AIR LOSS SYSTEM K 2oem ALT AIRE ALTERNATING PRESSURE WITH ON DEMAND LOW AIR LOSS SYSTEM US INTERNATIONAL PATENTS PENDING Ple...

Страница 2: ...ice 1 866 KAP MED 1 866 527 6331 Technical Support Service 1 951 340 4366 Email sales kapmedical com service kapmedical com www kapmedical com FDA Registered Company California FDA Registered Company...

Страница 3: ...ail Entrapment Risk Notification 9 Unit Overview 11 Explanation of Symbols Used 13 Mattress Overview 15 Unpacking the System 16 Mattress System Set Up 17 Operating Instructions 18 CPR Function 23 Pati...

Страница 4: ...pport combustion Failure to observe this warning can result in severe fire property damage and cause injury or death Entrapment may occur Patient entrapment with bed side rails and mattress may cause...

Страница 5: ...harmful interference received including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for compliance could void the user s a...

Страница 6: ...2 LPM Support Surface Inflation Time 5 15 Minutes Patient Comfort Pressures Alternating Pressure Soft Pressure 6 5 mmHg K 1 K 2 Firm Pressure 32 5 mmHg K 1 31 5 mmHg K 2 of high AP pressure setting A...

Страница 7: ...n height replacement mattresses available along with 3 or 5 mattress overlays Packaging 1 piece per box Patented Low Air Loss top sheet on K 2 and k 2oem models only Optional mattress with Kevlar line...

Страница 8: ...California117 Optional California TB 106 TB 129 16 CFR 1632 16 CFR 1633 BS 6607 CRIB 5 BS 597 1 BS 597 2 compliant mattresses lined with Kevlar fire barrier available Kevlar lining based on flammabil...

Страница 9: ...control unit is not blocked and kept away from any heat sources or radiators during the operation of the unit Care should be taken such that the power cord of the control unit is not pinched or has an...

Страница 10: ...patient is unique Only the patient s medical care provider is familiar with the patient s unique medical condition and needs Only the patient s medical care provider and or the dealer from whom you o...

Страница 11: ...ces TSS which support the patient on an air mattress or specialized foam layer may present an increased risk of entrapment for some patients The benefit of TSS product use must be weighed against the...

Страница 12: ...Thermoplastic 94V 0 fire retardant enclosure houses a compressor main PCB display panel a short circuit over voltage protection with single dual fuse a quick connection and disconnection CPR deflatio...

Страница 13: ...s Owner s Manual Page 12 Refer to the Explanation of Symbols Used chart on page 13 for a cross reference of Display Key descriptions Unit Display Labels K 1 DERMA KARE K 1oem ALT AIRE K 2 KARE ZONE K...

Страница 14: ...STATIC T or Selects Static Therapy mode LOW AIR LOSS Y or or Activates Low Air Loss mode ALTERNATING PRESSURE AP or or Selects A P mode AP TIME TT or Selects AP cycle time FOWLER U or Fowler Mode The...

Страница 15: ...luded with each model SYMBOL EXPLANATION No Sharp Objects Low Heat Setting Do Not Dry Clean Do Not Bleach No Open Flames Normal Cycle Do Not Iron Latex Free Bolstered Mattress Even Bolstered Mattress...

Страница 16: ...top sheet has a special multi chambered air distribution layers which administers low air loss relief directly underneath the patient Top layer made out of urethane coated 70 Denier nylon or Dartex o...

Страница 17: ...of moving bed components before placing a patient on the bed and that the mattress system is fully inflated Operate all bed frame motorized functions through their full range of motion to be certain...

Страница 18: ...mattress system care should be taken such that the mattress is placed directly on the bed frame Figure 1 B Page 16 Unroll the Replacement Mattress and place it on the bed frame BF There are ten nylon...

Страница 19: ...m initialization routine for a few seconds Once the routine is completed the display D will read KAP MEDICAL STANDBY K 1oem K 2oem During initial power up when power cord Q is plugged into the power s...

Страница 20: ...atient s body There should be a minimum of 3 to 4 finger width clearance between the bottom of the patient and the safety foam base on an overlay there is no safety foam base Repeat this procedure unt...

Страница 21: ...even numbered air cushions deflate to the set percentage of the patient comfort high pressure in the first half of the AP cycle and vice versa for the second half of the cycle and continue back and f...

Страница 22: ...is factory programmed to a 35 or 45 angle depending on the customer s requirements It uses a 3 6V Lithium battery that can be replaced using KAP Medical part number 100622 S When the battery is first...

Страница 23: ...Cushion K 140 OPTIONAL SAC Optional foot support air cushion can be used to support patient s feet and to provide zero interface pressures in the heel area FOAM AIRE MATTRESS AS A NON POWERED MATTRESS...

Страница 24: ...mattress for a CPR procedure pull the hose V from the control unit connector press connector latches then pull connector If the mattress is equipped with bolsters and or air pad unplug the correspond...

Страница 25: ...unit flange connector PLEASE NOTE Before using the mattress please make sure that the mattress deflate connector is re connected back into the mattress deflate valve PATIENT TRANSPORTATION 1 Air Matt...

Страница 26: ...ray the exterior of the top and the bottom enclosures power cord and the cord plug with the prepared disinfectant detergent solution Using a damp cloth wipe down the sprayed surface cleanly Note Do no...

Страница 27: ...ote The Foam Aire mattresses have a Kevlar fire retardant sleeve sock barrier inside the cover Care should be taken if removing the cover for cleaning Before attempting to clean the mattress remove th...

Страница 28: ...o power source 3 Check power source has power and turn it ON 4 Wait till the power source has power 5 Send control unit back to factory for repair C Control Unit not responding 1 Unit locks up 1 Unplu...

Страница 29: ...ressure setting or 7 75 mmHg of high comfort pressure setting Use the Soft Firm keys to toggle between AP Low modes To end routine and accept setting press Power key Routine will auto time out K 2 ELI...

Страница 30: ...ICAL be liable for any loss direct indirect incidental or special damages arising out of or in connection with the use of this product The control unit warranty does not cover normal maintenance such...

Страница 31: ...K 1 K 2 Series Owner s Manual Page 30 NOTES Unit S N __________________________________ Mattress S N _______________________________ Auto Fowler S N ____________________________...

Страница 32: ...nnected securely to the control unit Plug the hospital grade power cord provided with the unit into a three pronged hospital socket The display will read KAP MEDICAL STAND BY Press POWER key SB to gre...

Страница 33: ...tress hose assembly is connected securely to the control unit Plug the hospital grade power cord provided with the unit into a three pronged hospital socket The amber light will illuminate Press POWER...

Страница 34: ...o set the patients height and weight Patient comfort settings will be automatic when done with settings Adjust the SOFT FIRM knob K to bypass automatic patient comfort pressure settings Actual mattres...

Страница 35: ...e power cord provided with the unit into a three pronged hospital socket The amber light will illuminate Press POWER key SB to green light position and then press Select key S until MAX Inflate LED W...

Отзывы: