BED RAIL ENTRAPMENT RISK NOTIFICATION 

 

 

NOTICE TO PATIENT, PATIENT’S FAMILY AND/OR PRIMARY DAY-TO-DAY CAREGIVER 

 

DO NOT use this product without first completely reading and understanding this Bed Rail Entrapment Risk Notification 
and any additional instructional material such as owner’s manual, instruction sheets and on-product warnings supplied with 
this product.  If you are unable to fully understand this Bed Rail Entrapment Risk Notification, the on-product warnings or 
any additional instructional materials, contact the patient’s health care provider and/or your equipment provider before 
using this equipment.  Failure to understand and comply with the information contained in this Bed Rail Entrapment Risk 
Notification can result in serious injury or death. 

Entrapment within the bed rail        Entrapment under the bed rail       Entrapment between the      Entrapment between the  
                                                                                                                         bed rail and mattress            head or foot board and the 

 

                                                                                                                                  

end of the mattress

 

 

 
 
 
 
 
 

 Entrapment under the bed rail at the ends        Entrapment between split bed rails            Entrapment between the end of  
of the bed rail 

 

 

 

                                                                                 the rail and the side edge of the  

 

 

 

 

 

 

 

 

 

 

 

          headboard or foot board 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

 
 

 

RISK OF ENTRAPMENT 

 

Bed Rail Entrapment is a known risk in the use of bed’s equipped with bed rails. 

 

Every patient is unique.  Only the patient’s medical care provider is familiar with the patient’s unique medical condition and 
needs.  Only the patient’s medical care provider and/or the dealer from whom you obtained this equipment, upon proper 
assessment of the patient’s medical condition and needs, can evaluate whether this equipment is appropriate for use by any 
particular patient and assist the patient, the patient’s family and/or the patient’s primary day-to-day caregiver in assessing 
the Risk of Entrapment. 

 

Proper patient assessment, equipment selection, frequent patient monitoring, and compliance with instructions, warnings 
and this Bed Rail Entrapment Risk Notification is essential to reduce the risk of entrapment. 

Accessories have been developed in the industry to reduce the openings in existing bed systems that could cause 
entrapment.  Any modification through the use of accessories must be used in conjunction with proper patient assessment 
prior to intervention.  For a full discussion on this topic, see the Hospital Bed Safety Workgroup’s “A Guide for Modifying 
Bed Systems and Using Accessories to Reduce Risk of Entrapment” found at 

Conditions such as restlessness, mental deterioration and dementia or seizure disorders (uncontrolled body movement), 
sleeping problems, and incontinence can significantly impact a patient’s risk of entrapment, Pediatric patients or patients 
with small body size may also have an increased risk of entrapment. 

 

 

Содержание K-1 Series

Страница 1: ...SYSTEM K 2 ELITE KARE ZONE DIGITAL ALTERNATING PRESSURE WITH ON DEMAND LOW AIR LOSS SYSTEM K 2oem ALT AIRE ALTERNATING PRESSURE WITH ON DEMAND LOW AIR LOSS SYSTEM US INTERNATIONAL PATENTS PENDING Ple...

Страница 2: ...ice 1 866 KAP MED 1 866 527 6331 Technical Support Service 1 951 340 4366 Email sales kapmedical com service kapmedical com www kapmedical com FDA Registered Company California FDA Registered Company...

Страница 3: ...ail Entrapment Risk Notification 9 Unit Overview 11 Explanation of Symbols Used 13 Mattress Overview 15 Unpacking the System 16 Mattress System Set Up 17 Operating Instructions 18 CPR Function 23 Pati...

Страница 4: ...pport combustion Failure to observe this warning can result in severe fire property damage and cause injury or death Entrapment may occur Patient entrapment with bed side rails and mattress may cause...

Страница 5: ...harmful interference received including interference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for compliance could void the user s a...

Страница 6: ...2 LPM Support Surface Inflation Time 5 15 Minutes Patient Comfort Pressures Alternating Pressure Soft Pressure 6 5 mmHg K 1 K 2 Firm Pressure 32 5 mmHg K 1 31 5 mmHg K 2 of high AP pressure setting A...

Страница 7: ...n height replacement mattresses available along with 3 or 5 mattress overlays Packaging 1 piece per box Patented Low Air Loss top sheet on K 2 and k 2oem models only Optional mattress with Kevlar line...

Страница 8: ...California117 Optional California TB 106 TB 129 16 CFR 1632 16 CFR 1633 BS 6607 CRIB 5 BS 597 1 BS 597 2 compliant mattresses lined with Kevlar fire barrier available Kevlar lining based on flammabil...

Страница 9: ...control unit is not blocked and kept away from any heat sources or radiators during the operation of the unit Care should be taken such that the power cord of the control unit is not pinched or has an...

Страница 10: ...patient is unique Only the patient s medical care provider is familiar with the patient s unique medical condition and needs Only the patient s medical care provider and or the dealer from whom you o...

Страница 11: ...ces TSS which support the patient on an air mattress or specialized foam layer may present an increased risk of entrapment for some patients The benefit of TSS product use must be weighed against the...

Страница 12: ...Thermoplastic 94V 0 fire retardant enclosure houses a compressor main PCB display panel a short circuit over voltage protection with single dual fuse a quick connection and disconnection CPR deflatio...

Страница 13: ...s Owner s Manual Page 12 Refer to the Explanation of Symbols Used chart on page 13 for a cross reference of Display Key descriptions Unit Display Labels K 1 DERMA KARE K 1oem ALT AIRE K 2 KARE ZONE K...

Страница 14: ...STATIC T or Selects Static Therapy mode LOW AIR LOSS Y or or Activates Low Air Loss mode ALTERNATING PRESSURE AP or or Selects A P mode AP TIME TT or Selects AP cycle time FOWLER U or Fowler Mode The...

Страница 15: ...luded with each model SYMBOL EXPLANATION No Sharp Objects Low Heat Setting Do Not Dry Clean Do Not Bleach No Open Flames Normal Cycle Do Not Iron Latex Free Bolstered Mattress Even Bolstered Mattress...

Страница 16: ...top sheet has a special multi chambered air distribution layers which administers low air loss relief directly underneath the patient Top layer made out of urethane coated 70 Denier nylon or Dartex o...

Страница 17: ...of moving bed components before placing a patient on the bed and that the mattress system is fully inflated Operate all bed frame motorized functions through their full range of motion to be certain...

Страница 18: ...mattress system care should be taken such that the mattress is placed directly on the bed frame Figure 1 B Page 16 Unroll the Replacement Mattress and place it on the bed frame BF There are ten nylon...

Страница 19: ...m initialization routine for a few seconds Once the routine is completed the display D will read KAP MEDICAL STANDBY K 1oem K 2oem During initial power up when power cord Q is plugged into the power s...

Страница 20: ...atient s body There should be a minimum of 3 to 4 finger width clearance between the bottom of the patient and the safety foam base on an overlay there is no safety foam base Repeat this procedure unt...

Страница 21: ...even numbered air cushions deflate to the set percentage of the patient comfort high pressure in the first half of the AP cycle and vice versa for the second half of the cycle and continue back and f...

Страница 22: ...is factory programmed to a 35 or 45 angle depending on the customer s requirements It uses a 3 6V Lithium battery that can be replaced using KAP Medical part number 100622 S When the battery is first...

Страница 23: ...Cushion K 140 OPTIONAL SAC Optional foot support air cushion can be used to support patient s feet and to provide zero interface pressures in the heel area FOAM AIRE MATTRESS AS A NON POWERED MATTRESS...

Страница 24: ...mattress for a CPR procedure pull the hose V from the control unit connector press connector latches then pull connector If the mattress is equipped with bolsters and or air pad unplug the correspond...

Страница 25: ...unit flange connector PLEASE NOTE Before using the mattress please make sure that the mattress deflate connector is re connected back into the mattress deflate valve PATIENT TRANSPORTATION 1 Air Matt...

Страница 26: ...ray the exterior of the top and the bottom enclosures power cord and the cord plug with the prepared disinfectant detergent solution Using a damp cloth wipe down the sprayed surface cleanly Note Do no...

Страница 27: ...ote The Foam Aire mattresses have a Kevlar fire retardant sleeve sock barrier inside the cover Care should be taken if removing the cover for cleaning Before attempting to clean the mattress remove th...

Страница 28: ...o power source 3 Check power source has power and turn it ON 4 Wait till the power source has power 5 Send control unit back to factory for repair C Control Unit not responding 1 Unit locks up 1 Unplu...

Страница 29: ...ressure setting or 7 75 mmHg of high comfort pressure setting Use the Soft Firm keys to toggle between AP Low modes To end routine and accept setting press Power key Routine will auto time out K 2 ELI...

Страница 30: ...ICAL be liable for any loss direct indirect incidental or special damages arising out of or in connection with the use of this product The control unit warranty does not cover normal maintenance such...

Страница 31: ...K 1 K 2 Series Owner s Manual Page 30 NOTES Unit S N __________________________________ Mattress S N _______________________________ Auto Fowler S N ____________________________...

Страница 32: ...nnected securely to the control unit Plug the hospital grade power cord provided with the unit into a three pronged hospital socket The display will read KAP MEDICAL STAND BY Press POWER key SB to gre...

Страница 33: ...tress hose assembly is connected securely to the control unit Plug the hospital grade power cord provided with the unit into a three pronged hospital socket The amber light will illuminate Press POWER...

Страница 34: ...o set the patients height and weight Patient comfort settings will be automatic when done with settings Adjust the SOFT FIRM knob K to bypass automatic patient comfort pressure settings Actual mattres...

Страница 35: ...e power cord provided with the unit into a three pronged hospital socket The amber light will illuminate Press POWER key SB to green light position and then press Select key S until MAX Inflate LED W...