DN1769-1809
30
6 - Troubleshooting
Table 4: Reset Types and Descriptions
Table 5: AC and DC Power LED Status Indicators
Jumpers
Heartbeat Patterns
Resets
Continuous Short Pulses
Soft Reset:
When JP1 and JP2 are ON, the KTES will reset on a) power up, b)
pushbutton, or c) EntraPass software 'Manual operator soft reset':
•
All KTES memory definitions and parameters are verified and
kept intact if still valid.
•
The internal event buffer is maintained if still valid.
•
IP address is kept if valid.
•
The KTES generates the appropriate message: a) 'Power ON
Soft Reset' b) 'Manual Pushbutton Soft Reset' c) 'Operator
Soft Reset'.
3 Long Pulses
Forced Default Static:
When JP1 is ON and JP2 is OFF:
•
Same as 'Soft Reset' condition, except IP address is forced to
the default static
IP: 192.168.1.2.
4 Short Pulses
Hard Reset:
When JP1 is OFF and JP2 is ON:
•
The default installer PIN (
8888
) is restored.
•
All KTES memory is settled to default values.
•
Internal event buffer is cleared.
•
IP address is kept if valid.
•
KTES generates the message, 'KTES Hard Reset'.
•
Internal RTC (Real Time Clock) and clock are settled to the
default time and date values January 1st 2009, 00:00:00.
Continuous Long Pulses
Factory Default:
When JP1 and JP2 are OFF:
•
The default installer PIN (
8888
) is restored.
•
All KTES memory is settled to default values.
•
Internal event buffer is cleared.
•
KTES generates the message 'KTES Factory Default Reset'.
•
Internal RTC and clock are settled to the default time and date
values January 1st 2009, 00:00:00.
AC Power LED
DC Power LED
Status Indicators
ON
ON
•
The AC power or external AC source is present.
•
The DC power level is sufficient for all DC operations such as the readers,
outputs and the 12V AUX.
OFF
ON
•
The KTES is running on the 12V rechargable backup battery only.
•
The DC power supply has been connected with reverse polarity,
for CE compliant models only.
Содержание Telephone Entry System
Страница 1: ...DN1769 1809 Installation Manual Kantech Telephone Entry System ...
Страница 2: ......
Страница 4: ...DN1769 1809 iv ...
Страница 21: ...DN1769 1809 15 Kantech Telephone Entry System Installation Manual Figure 8 PCB view of main board ...
Страница 22: ...DN1769 1809 16 Figure 9 KTES Wiring Example with an External Controller UL Compliant North America ...
Страница 40: ...DN1769 1809 34 ...