DN1315-1007
16
KT-300 Door Controller Installation Manual
Applying Power
1. After all wiring is completed, apply power to the KT-300.
2. Connect the battery leads to the battery.
3. Then, connect the AC transformer.
NOTE:
Do not connect the power until all wiring is completed.
Assigning the KT-PC4216 Module
Follow the Instructions below for assigning and programming your KT-PC4216 module.
1. Establish communication between EntraPass and the controller.
2. Remove the tamper switch wire (or only the wire if tamper switch is not used).
3. A serial number, the type of module and on which controller it is connected should be displayed on the screen.
4. From the EntraPass user interface, go to the controller definition window and select the functionality of the
module and enter the serial number in the appropriate field (refer to
Chapter 4, Defining Devices
of your
EntraPass Reference Manuel
for more details).
NOTE:
Do not forget to reconnect the tamper switch (or the wire, if there is no tamper switch).
NOTE:
If you are using a KT-PC4204 in “repower” mode on the same loop, do not use the first relay of the KT-PC4216.
KT3-LCD - Kantech LCD Time & Date Display Module
KT3-LCD Introduction
The KT3-LCD module is an LCD readout module with integrated keypad
which provides date and time via a 32-character liquid crystal display.
KT3-LCD Specifications
•
Connects to control panel via 4-wire Combus
•
Current draw: 50 mA (from Combus)
•
Input status (green), AC Fail (red) and Trouble (yellow) status
lights
Unpacking the KT3-LCD
The KT3-LCD package includes the following parts/items:
•
One KT3-LCD keypad
•
Four mounting screws
Mounting the KT3-LCD
The keypad should be mounted where it is accessible to designated points to entry/exit. Once a dry and secure location is
selected, perform the following steps to mount the keypad:
1. Remove the keypad back plate by loosening the screw located at the base of the unit.
2. Secure the keypad back plate to the wall in the desired location. Use the included screws.
NOTE:
Power is drawn from
the Combus. May
require a KT-PC4204
power supply module
if drawing too much
power from the
Combus.
Содержание Door Controller Innovative and Powerful KT-300
Страница 1: ...DN1315 1007 V01 02 KT 300 Door Controller Installation Manual ...
Страница 2: ......
Страница 27: ...DN1315 1007 20 KT 300 Door Controller Installation Manual KT 300 Wiring Diagram North American Version ...
Страница 28: ...DN1315 1007 21 KT 300 Door Controller Installation Manual KT 300 Wiring Diagram EU Version ...