Kanomax ANEMOMASTER Series Скачать руководство пользователя страница 7

6.4.1 Printing with Single Parameter Output Setting ..................................................... 26 

6.4.2 Digital Output with Single Parameter Output Setting ........................................... 26 

6.5 Analog Output (Optional) ........................................................................................ 27 

7. Function Settings ..................................................................................................... 28

 

7.1 Changing Date and Time ......................................................................................... 28

 

7.2 Other Function Settings ........................................................................................... 29

 

7.2.1 Setting Procedure .................................................................................................. 29 

7.2.2 Dip Switch Setup Chart ......................................................................................... 30 

8. Cleaning Probe ......................................................................................................... 31

 

9. Specifications ............................................................................................................ 32

 

10. Measurement Principles ....................................................................................... 33

 

10.1 Hot-wire Anemomaster Principle .......................................................................... 33

 

10.2 Air Volume Calculation ......................................................................................... 34

 

11. Air Velocity Compensation ................................................................................... 35

 

11.1 Influence of Air Temperature ................................................................................ 35

 

11.2 Influence of Atmospheric Pressure ........................................................................ 35

 

11.3 Influence of Air Composition ................................................................................ 35

 

12. Probe Directivity (Air Velocity) ........................................................................... 36

 

12.1 Horizontal Directivity ............................................................................................ 36

 

12.2 Vertical Directivity ................................................................................................ 36

 

13. Troubleshooting ..................................................................................................... 37

 

13.1 Batteries ................................................................................................................. 37

 

13.2 Initial Operation ..................................................................................................... 37

 

13.3 During Operation ................................................................................................... 37

 

13.4 Printing .................................................................................................................. 38

 

13.5 Digital Output ........................................................................................................ 38

 

13.6 Analog Output........................................................................................................ 38

 

14. Warranty and After-sales Service ........................................................................ 39

 

Содержание ANEMOMASTER Series

Страница 1: ...6113 6114 6115 Operation Manual Please read this operation manual carefully and understand the warnings described in this manual before operating the instrument Keep this manual handy for ready refer...

Страница 2: ...oulder Strap 1 Operation Manual 1 C size Manganese Batteries 6 Printer 1 Built in Thermal Printer Pressure Sensor 6113 07 1 Pos Neg Static Pressure Measurement Ports Spare Probe 6113 01 1 Air Velocity...

Страница 3: ...ted to the following Do not install the probe in an area where flammable gas is present Otherwise there is an increased risk of fire or even explosion Do not open the device or attempt to disassemble...

Страница 4: ...he device If unusual smells sounds or smoke emanate from the device or if liquids enter the device switch the device off immediately and take out the batteries and or unplug it from the power outlet O...

Страница 5: ...r near heater Otherwise the main body may become disfigured or the internal components may be damaged and no longer function properly When cleaning the device never use benzene paint thinners detergen...

Страница 6: ...eting Measurement Data 15 4 2 1 Deleting All Deleting All Stored Measurement Data 15 4 2 2 Deleting the Last Data Deleting a Single Measurement Data Last Stored 15 4 2 3 Deleting Selected Data Deletin...

Страница 7: ...Measurement Principles 33 10 1 Hot wire Anemomaster Principle 33 10 2 Air Volume Calculation 34 11 Air Velocity Compensation 35 11 1 Influence of Air Temperature 35 11 2 Influence of Atmospheric Press...

Страница 8: ...ressure Sensor Port Optional Approx 210 Extension Rod Approx 120 Operation Panel Cable LCD Display Lid Probe storage area Rotate Probe Probe Rest To be used only when measuring Caution When you close...

Страница 9: ...Bottom View Left Side View 1 Part names and Functions 2 Battery Compartment ROM Cassette Storage Area Built in Printer 0001 ROM Cassette Probe Number Display Window Printer Paper Cutter...

Страница 10: ...y In the function setting mode Use this key to exit setting While printing Use this key to stop printing Note that you cannot stop printing the data that has already been transmitted to the printer Ke...

Страница 11: ...m 1 Part Names and Functions 4 Approx 10 Wind Direction Mark Approx 33 Approx 150 Probe Number 001 Air Velocity Sensor Temp Compensation Sensor Temperature Sensor Approx 13 Approx 23 Approx 5 Cable Le...

Страница 12: ...1 4 Extension Rod Unit mm 1 Part Names and Functions 5 Approx 167 Max extended length 960 Approx 68 Approx 12 Approx 15 Connecting Probe Probe Extension Rod 1 2...

Страница 13: ...nese Alkaline or Ni Cd batteries Do NOT mix different types of batteries Mixing different types of batteries may cause battery leakage or damage to the instrument Batteries CANNOT be recharged by the...

Страница 14: ...below Make sure that the power is OFF when connecting or disconnecting the probe Do not squeeze the connector into the terminal ignoring the connector s angle or do not twist the connector after the...

Страница 15: ...ows up the instrument will become inoperable even when a measurement is being performed Also please note that the data will NOT be saved in this situation Display Icons Normal Mode Refer to 3 Normal M...

Страница 16: ...time for temperature measurement improves as the air velocity becomes faster When the air velocity is 1m s the response time is approximately 30 seconds Wait for the reading to become stable before ta...

Страница 17: ...g Pressure Tube Connect the pressure tube to the or port Connect the other end of the tube to the port e g duct where the pressure is to be measured When the pressure to be measured is positive connec...

Страница 18: ...ey to change the screen in the order of 2 Air Temperature Measurement Screen 3 Pressure Measurement Screen optional for 6113 and 6114 1 Air Velocity Measurement Screen 2 Air Temperature Measurement Sc...

Страница 19: ...mode screen Air Velocity Measurement Mode is displayed In the default setting the range is 0 10m s and each scale is equivalent to 2m s The value on the right end of the bar graph changes Now the ran...

Страница 20: ...layed Once you turn the power off the time constant will revert to the default setting of 1 second What is Time Constant Time Constant is moving average deviations over a certain period of time If you...

Страница 21: ...Normal Measurement screen Measurement Mode is displayed The average value of the data over the time the key is pressed is stored as a set of data Sampling is performed every one second you will hear...

Страница 22: ...en Press key for over a second in the Normal Measurement screen Measurement Mode This procedure can be performed in any measurement mode of measuring Air Velocity Air Temperature and Pressure n xx sho...

Страница 23: ...city Air Temperature and Pressure When you hear a beep sound the data is deleted and the total amount of the stored data is displayed Then it will return to the screen showing the stored measurement d...

Страница 24: ...d Measurement Data Display 1 Normal Measurement Display 2 Average Value Display When the average value shows up the total amount of stored measurement data is displayed at the bottom In this mode ever...

Страница 25: ...key each of the stored measurement data is displayed as follows Air Temperature Pressure Air Velocity Also press keys to display other data pertaining to other data numbers In likewise every time you...

Страница 26: ...upwards toward you Insert the leading edge of the roll paper underneath the roller Roller Roll Paper Install the roll paper with the head lever pulled down There is a paper sensor here As shown in the...

Страница 27: ...ut from the roller will not be caught in the roller again 7 Install the roll paper into the holder as tightening the roll Close the printer cover making sure that the paper comes out of the paper ejec...

Страница 28: ...key to print out the calculated values Average Maximum and Minimum of all measurement parameters Example of Data Print Out Calculation Results 6 Data Output 21 Printout Date YYYY MM DD Printout Time H...

Страница 29: ...n Result Measurement Data Information on Function Set up Avg m s Baud Rate Buzzer ON OFF Air Velocity Unit Air Temperature Unit Pressure Unit Analog Output Rang AirVelocity Analog Output Range Air Tem...

Страница 30: ...ltage drop occurs and the instrument s voltage becomes lower than the level that it requires for operation which may cause the instrument to stop working Depending on the battery s condition even when...

Страница 31: ...ing refer to the operation manual of your PC Connecting the instrument to a PC 1 Connect the instrument to a PC by inserting a connecting cable into RS232C terminal on the instrument 2 Turn ON the ins...

Страница 32: ...ature Pressure Without Pressure Measurement Function Air Velocity Air Temperature 0000000 Receive Interrupt Enter N After the command is received AN will be returned and the reception will be interrup...

Страница 33: ...o Output Single Parameter of Measurement Data When this function is ON the only value displayed on the Normal Measurement screen Measurement Mode during the operation will be printed out or sent as a...

Страница 34: ...T 90 V 32 o F 32 212 o F T 180 V 32 o F Pressure P 5 5 kPa P 10 V 5 kPa 2 2 kPa P 4 V 2 kPa Output Range The output is linear output with the minimum value of 0V and maximum value of 1V The output dat...

Страница 35: ...Month 5 Minute 3 Date Next the numeric value indicating month flashes Use and keys to adjust the month Then press key Next the numeric value indicating date flashes Use and keys to adjust the date The...

Страница 36: ...ey Keep holding down key until you see a display like the one shown on the left The b0 on the left indicates the bit number and 01 on the right shows the bit status See 7 2 2 Dips Switch Setup Chart i...

Страница 37: ...g Wind Velocity 0 5m s b5 00 b6 00 0 10m s b5 01 b6 00 0 25m s b5 00 b6 01 0 50m s b5 01 b6 01 0 1000FPM b5 00 b6 00 0 2000FPM b5 01 b6 00 0 5000FPM b5 00 b6 01 0 9999FPM b5 01 b6 01 Wind Temp 0 50 b5...

Страница 38: ...strument in an unclean environment it is recommended that the sensor is cleaned right after use 8 Cleaning Probe 31 Clean the sensor of the probe in an ultrasonic cleaner for approx 10 20 sec Do not c...

Страница 39: ...Raw data display Calendar function Bar graph display indicating air velocity Output Digital Output RS 232C 4800 9600 19200 and 38400 bps for outputting to PC Printer Output 2 Print out calculation re...

Страница 40: ...ere H Heat Dissipation T Sensor Temperature Ta Air Temperature U Air Velocity a b Constant The Heat Dissipation H can also be expressed by the following formula from the sensor resistance R and curren...

Страница 41: ...be obtained In addition since the diffusion resistance is dependent on temperature temperature compensation resistance is employed for the resistance 10 2 Air Volume Calculation Average air velocity...

Страница 42: ...nt air temperature changes even when the air velocity is consistent In order to prevent such influence the instrument is equipped with a temperature compensation circuit for measuring and compensating...

Страница 43: ...tivity Air Velocity 12 1 Horizontal Directivity 12 2 Vertical Directivity 12 Probe Directivity 36 180 0 90 90 When Air Velocity is 5m s When Air Velocity is 5m s Wind Direction Mark 0 180 90 90 Wind D...

Страница 44: ...is not correct You can change the Air Velocity unit m s FPM and the Air Temperature unit o F 29 13 3 During Operation Symptom Possible Cause s Solution s Refer To Page No Reading is displayed as Meas...

Страница 45: ...t Check to ensure printer paper is properly set in the roller 19 E 2 is displayed on the screen The battery is low Turn the power OFF and replace the batteries 6 Printer Head has overheated due to con...

Страница 46: ...e owner alteration accident electrical current fluctuations failure to follow operating maintenance or environmental instructions prescribed in the PRODUCT s instruction manual provided by KANOMAX or...

Страница 47: ...s after production cessation of the PRODUCT This storage period of repair parts is considered as the period during which KANOMAX can provide repair service For more information please contact your sal...

Страница 48: ...usa com Japan Asia KANOMAX JAPAN INC 2 1 Shimizu Suita City Osaka 565 0805 Japan TEL 81 6 6877 0183 FAX 81 6 6877 5570 URL http www kanomax co jp E Mail sales kanomax co jp China Shenyang Kano Scienti...