19
7. Press the EXE button to begin the cleaning process.
8. Remove the card when the process is completed and discard.
Manual Cleaning
As you use your printer and Heat Roller Unit, dust and other particles may accumulate inside the
printer before you actually need to replace the ribbon. Periodically, manually cleaning
procedures should be performed to remove dust and other contaminants.
Cleaning the Platen and Capstan Rollers
1. Power OFF the printer, Heat Roller Unit and remove the power cord.
2. Remove the 4 phillips screws on the side cover of the Heat Roller Unit.
3. Open the front access cover of the Heat Roller Unit by depressing the release button.
4. With the front access cover open, turn the manual rotation knob clockwise to advance the
rollers and clean the capstan and platen rollers with an alcohol swab.