OWDMANUAL 1114
KAM CONTROLS, INC.
5
S P E C I F I C AT I O N S C O N T I N U E D
DIMENSIONAL DRAWINGS 0-100% MODELS
CALCULATING SHAFT LENGTH 0-100% MODELS
D1
Valve
Length
Main Pipe
Pipe OD
Determine minimum shaft length for proper insertion in the pipeline.
Off-the-shelf lengths are 12", 24", and 36".
TABLE 2-2
DIMENSIONS INSERTABLE OWD
®
SENSOR 0-100%
C
D
E
Custom Shaft
Lengths
A
B
F
G
H
FIG. 2-1
INSERTABLE
OWD
®
SENSOR 0–100%
A
B
C
D
E
F
G
H
INCHES
1.48
2.4
4.62
max 11.65
2.3
5.7
7
4.6
MM
38
61
117
296
58
145
178
117
Shaft Lengths are available in .5"
(12.7mm) increments.
Standard sizes are 24", 30", 36", 48",
and 60" (609.6mm, 762mm, 914.4mm,
1219mm, 1524mm).
*Seal housing dimensions vary according to flange size and pressure rating. 11.65" is the maximum length
required in calculating shaft length.
D1
+
Valve Length:
+
Pipe OD x .5:
+
Seal housing length
–
Probe factor
=
Total / minimum shaft length for proper
insertion distance
13"