Master/ slave mode
When linking the units together with no controller one unit must be set as the master unit, all others to slave units.
To set master:
Sound active mode
All switches are Off.
Auto mode
Dipswitch 9 + desired effect see above chart.
Slave mode
Set all slave units with dipswitch 10 on only.