MG sensor Adjustment
Related problem
Special Tools
Real note 100 pcs
MR test note 50 pcs
Medium
Work time
LCD
“1”(Up),“7”(Down)
“3”(Up), “9”(Down)
LED
0
0
“1”(Up), “7”(Down) “5” (Change Speed) “3”(Up), “9”(Down)
# CAL : MR
[P]
SET : 0
REF : 114
MIN : 0
AVR : 0
MAX : 0
[N]
SET : 0
REF : 114
MIN : 0
AVR : 0
MAX : 0
SP-2 ( 1000 )
Standard Value
(Unit: AD value)
Adjustment Procedure
Maintenance
1. Enter maintenance mode VID 1311
2. Count MR test note and check Min/Max value of MR.
Please set Min/Max value at “0” with VR11
3. Test real note
If Min value is over 10, It is stable.
If Min value is less 10, It is not stable with MR. Please
Adjust VR11 to make Mix value over 10.
4. Test again with MR test note and real note.
The value of MR test note should be “0” and real note
Should be over 10.