http://www.nexbill.co.kr
Chapter V. Maintenance Mode.
Some functions described in this chapter may not available depending on the Model.
The function not activated means the function is not available Logging Data functioned
between VID# to VID# are not available on KL-2000/2010.
1. How to enter Maintenance Mode
Turn on the Power Switch with pressing “Restart” key. Keep pressing “Restart” key approx
one second and then display indicates “PASS”(LED)/”Password”(LCD)
P
A
S
S
(PASS : LED type, Password: LCD type)
Press “Enter” and “2.0.0.0.”(Machine password) and “Enter”
Log in Mode
0
Indication of Maintenance Mode
2. How to escape from Maintenance Mode
To escape from Maintenance Mode, turn off the Power Switch.
3. How to execute function of Maintenance Mode
1. Select desired function by changing the number
2. Press “Enter” key to execute the function and press “Mode” key or “Enter” key
to terminate the function.
3. Press ten keys to set the number.
4. Function of Each Mode
NO
Mode
Function
31
Parameter save
To save the parameter.
34
Calibration data save
To backup the important data( Calibration data ).
35
Calibration data restore
To restore the important data( Calibration data ).
41
Parameter Reconfiguration
To initialize all parameters
42
Parameter Reconfiguration
To initialize parameter connected with motor
43
Parameter Reconfiguration
To initialize parameter connected with speed
44
Parameter Reconfiguration
To initialize parameter connected with sensor
45
Parameter Reconfiguration
To initialize parameter connected function