A.8 Technical specifications by appliance
Kalfire G60/48F, G65/44C, G70/44S
Gas
cat.
Gas
type
Connection
pressure
Load
MAX (Hi)
kW (input)
Use
m³/h
Orifice
Code
(mm)
Injector
Code
(mm)
Burner pressure
maximum
mbar
Burner pressure
minimum
mbar
Power
maximum
kW (output)
Return on
investment
class
Energy
efficiency
class (sc)*
Energy
efficiency
class (lc)**
12H
G20
20mbar
6.8
0.71
2.6
2.2
13.2
2.8
5.8
1
C
A
12E
G20
20mbar
6.8
0.71
2.6
2.2
13.2
2.8
5.8
1
C
A
12E+
G25
G20
25mbar
20mbar
6.8
6.8
0.71
0.71
2.6
2.6
2.2
2.2
13.2
13.2
2.8
2.8
5.8
5.8
1
1
C
C
A
A
I2(43.46 –
45.3 MJ/m3
(0°C))//I2K
G25.3 25 mbar
7.4
0.89
3.3
2.3
20.2
3.8
6.0
1
C
A
I2ELL
G20
20mbar
5.7
0.69
2.6
2.2
12.7
2.8
5.7
1
C
A
I2ELL
G25
20mbar
5.75
0.70
2.2
2.2
12.7
2.8
4.8
1
C
A
13+
G30
G31
28-30 mbar
37 mbar
7.3
0.22
1.7
1.5
14.6
1.8
5.5
1
1
D
D
A
A
13B/P
G30
28-30 mbar
7.3
0.22
1.7
1.5
14.6
1.8
5.5
1
D
A
13B/P
G30
50 mbar
7.4
0.23
1.4
1.5
15
2.2
5.6
1
D
A
NOX-class: 4
KALFIRE G80/59F, G88/55C, G90/55S
Gas
cat.
Gas type
Connection
pressure
Load
MAX (Hi)
kw (input)
Use
m³/h
Orifice
Code
(mm)
Injector
Code
(mm)
Burner pressure
maximum
mbar
Burner pressure
minimum
mbar
Power
maximum
kW (output)
Return on
investment
class
Energy
efficiency
class (sc)*
Energy
efficiency
class (lc)**
12H
G20
20mbar
8.03
0.85
3.2
2.4
15.1
5.9
6.64
1
C
A
12E
G20
20mbar
8.03
0.85
3.2
2.4
15.1
5.9
6.64
1
C
A
12E+
G25
G20
25 mbar
20mbar
8.03
8.03
0.85
0.85
3.2
3.2
2.4
2.4
15.1
15.1
5.9
5.9
6.64
6.64
1
1
C
C
A
A
I2(43.46 –
45.3 MJ/m3
(0°C))//I2K
G25.3 25 mbar
8.32
1.01
3.2
2.6
18.4
3.9
6.84
1
C
A
I2ELL
G20
20mbar
8.03
0.85
3.2
2.4
15.1
5.9
6.64
1
C
A
I2ELL
G25
20mbar
6.95
0.84
3.2
2.4
15
6
5.78
1
D
A
13+
G30
G31
28-30 mbar
37 mbar
7.78
0.24
2
1.6
21.3
4.2
5.13
2
D
D
A
A
13B/P
G30
28-30 mbar
7.78
0.24
2
1.6
21.3
4.2
5.13
2
D
A
13B/P
G30
50 mbar
7.78
0.24
2
1.6
21.3
4.2
5.13
2
D
A
NOX-class: 4
88
Содержание G Series
Страница 1: ...Installation instructions BALANCED FLUE GAS FIRES DON T COMPROMISE EN...
Страница 2: ......
Страница 4: ...4...
Страница 43: ...1 4 6 7 5 2 3 43...
Страница 45: ...1 3 2 5 4 6 7 8 8 7 45...
Страница 47: ...1 9 4 7 3 8 5 6 2 10 47...
Страница 49: ...5 1 2 3 7 4 6 8 10 9 9 49...
Страница 51: ...4 5 3 6 1 1 51...
Страница 52: ...7 2 7 7 2 2 8 52...
Страница 54: ...4 5 2 1 1 3 54...
Страница 55: ...9 8 6 7 1 55...
Страница 57: ...5 6 7 8 3 2 2 1 57...
Страница 58: ...9 4 4 8 58...
Страница 60: ...5 2 9 6 2 1 4 3 60...
Страница 61: ...7 7 10 11 8 61...
Страница 63: ...1 7 7 3 4 6 2 7 63...
Страница 64: ...2 4 4 5 5 8 64...
Страница 66: ...7 4 5 6 1 8 9 66...
Страница 67: ...3 3 11 2 10 10 12 67...
Страница 69: ...1 2 6 6 8 8 9 7 7 4 With gas type G30 log 4 to be placed at extreme right 3 4 5 11 69...
Страница 72: ...10 2 1 9 11 3 3 4 5 5 7 6 72...
Страница 73: ...13 12 12 12 8 73...
Страница 76: ...3 1 6 5 4 2 13 76...
Страница 77: ...14 7 10 11 8 12 12 Other side Divide 15 cryptonite and 16 ash 77...
Страница 80: ...3 4 5 7 1 3 4 5 6 1 4 5 1 3 4 1 3 2 1 2 3 1 3 1 2 4 5 1 6 2 6 7 14 12 11 11 3 80...
Страница 81: ...3 4 5 7 8 1 3 4 7 9 10 8 3 4 5 6 7 8 1 3 4 5 6 7 8 1 3 4 5 6 7 1 9 10 8 15 13 81...
Страница 84: ...4 3 5 2 3 4 5 1 2 3 4 5 1 1 2 3 4 1 1 2 1 1 1 2 1 1 1 1 1 2 3 4 5 6 6 1 1 1 14 11 84...
Страница 87: ...Wiring diagram for SDS domo cable as shut down switch Fig 32 SDS domo cable shut down switch 87...
Страница 94: ...94...
Страница 95: ...95...
Страница 96: ...Gelo rveldweg 21 5951 DH Belfeld info kalfire nl KALFIRE COM DON T COMPROMISE REF V01 2019 EN...