background image

Installation 

instructions

BALANCED-FLUE GAS FIRES

DON’T COMPROMISE.

EN

Содержание G Series

Страница 1: ...Installation instructions BALANCED FLUE GAS FIRES DON T COMPROMISE EN...

Страница 2: ......

Страница 3: ...37S G160 41F G165 37C G170 37S for gas type G20 G25 and G30 Balanced flue gas fires Kalfire GP GP60 59F GP65 55C GP70 55S GP60 79F GP65 75C GP70 75S GP75 59F GP80 55C GP85 55S GP80 54T GP85 50R GP105...

Страница 4: ...4...

Страница 5: ...corative elements Kalfire GP80 54T and GP85 50R series 74 A 6 14 Placing decorative elements Kalfire G105 59 series 78 A 6 15 Placing decorative elements Kalfire G105 79 series 82 A 7 Wiring diagram 8...

Страница 6: ...he original document Disclaimer All rights reserved No part of this manual may be copied distributed or translated into other languages in full or in part without the prior written permission of Kalfi...

Страница 7: ...d by neglect improper use and or gross negligence 9 If the repair or delivery of individual parts be carried out by another manufacturer or by a professional technical fitter who has not been approved...

Страница 8: ...te 0 07 W m K A gap should also be left between the fireplace and the insulated fire resistant material The materials used for the surround of the gas fire need to be heat resistant and fire free The...

Страница 9: ...azard WARNING Make sure that flammable materials such as curtains and furniture are at least 100 cm from the fireplace If a fireguard is used this distance must be at least 40 cm wallpaper with which...

Страница 10: ...ion chamber to the floor be smaller than 10 cm a heat resistant fireguard floor plate larger than 30 cm or a stone should be placed Danger of combustion FIRE HAZARD Do not touch the appliance The gas...

Страница 11: ...ontrolled by the iMatch App on a smartphone or tablet This is only possible if the gas fire is equipped with the optional iMatch interface that serves as the receiver 3 Description The following secti...

Страница 12: ...e from the configurations in the appendices See flue duct configurations 1 through 6 on page 35 A chimney calculation is made for the roof pass through and the wall pass through The chimney calculatio...

Страница 13: ...e disconnected the following steps should be observed 1 Remove the automatic burner relay from the technical unit 2 Disconnect the earth wire on the automatic burner relay 3 Unscrew the bolt connected...

Страница 14: ...describes technical unit connection and the gas supply Cleaning and testing the gas fire Gas measurement Check the pre pressure of the gas connection after installation Carry out this measurement to...

Страница 15: ...and assemble the gas fire 1 Place the front glass in the appliance 2 Unscrew two bolts A from each support leg 3 To ensure that the support legs are on the desired height you might have to saw the to...

Страница 16: ...power supply cable 4 Connect the white plug to the ionisation cable 5 Place the ionisation cable covered by the black surround at the end 5 2 2 Adjusting the stone support The gas fire is equipped wi...

Страница 17: ...e is equipped with a pre pressure measuring nipple and a burner pressure measure nipple An arrow has been added to the rear side of the gas valve that indicates the gas flow direction An orifice that...

Страница 18: ...n all cases it is important that there is sufficient ventilation The temperature on the top of the appliance is very high Under no circumstances may the surround be insulated Always follow the install...

Страница 19: ...75 cm Connecting with convection hood The convection hood is mounted on the appliance in the factory and so cannot be installed afterwards The convection hood ensures a delivery of controlled heat in...

Страница 20: ...nfiguration of the decorative elements on page 42 85 Installing the technical unit Place the technical unit in an accessible place preferably in the side wall of the surround Take the choice of materi...

Страница 21: ...active and the remote control will display the notification 04F The flame stays in a blocked position so long as the switch is inactive When the switch is operated it will open and the flame will be...

Страница 22: ...pp on page 26 After configuration you can operate the appliance with the iMatch app the green LED will be on and visible in the iMatch interface If the red and green LED lights are flashing you can ca...

Страница 23: ...rting up 2 Day of the week in numbers 1 7 Monday is 1 a glow lamp Indicator for the LED lighting 3 RF signal a flashing icon indicating that the appliance is beyond the reach of the remote control 4 f...

Страница 24: ...ts to flash in the top left hand corner of the display 4 Press the right button to display TCOM temperature comfort TCOM indicates the maximum temperature during all set time segments 5 Set the desire...

Страница 25: ...elivery Use the instruction delivered with bthe new powder for refilling the Natural Spark Generator increments of 0 5 C 6 Confirm by pressing the centre button 7 TECO temperature ECO will now appear...

Страница 26: ...replace Change the name of the room s present Select the room you want to change In the screen that appears next you are able to change the name 3 Wizard click on Wizard and follow the instruction to...

Страница 27: ...ill start at 100 flame intensity 2 Setting the flame intensity Press and hold down the black dot Move your finger over the circle to set the flame intensity The percentage will increase and decrease w...

Страница 28: ...roleum based solvents solvents scouring powders abrasive materials steel wool scrubbing or scouring pads scrapers razor blades paper ceramic stove cleaners Aggressive cleaning materials 7 Maintenance...

Страница 29: ...by moving the handles down Twist the metal cover strips step 1 back into its original position by using the protruding lip at the upper side of the strip 7 1 4 Door dismantling and assembly front and...

Страница 30: ...the automatic burner relay are tested The fireplace is automatically switched off and stays down until it is turned on again manually 7 2 1 Removing or resetting a malfunction The automatic burner rel...

Страница 31: ...The yellow light will start flashing rapidly now 7 Immediately within 10 seconds press and hold it down until the word LINK starts flashing on the display 8 Wait until LINK 1 appears and release 9 Pre...

Страница 32: ...side the technical unit See Wiring diagram on page 86 3 Check if there is sufficient 24V D C power supply 4 Check the ignition cable for damages and check the connection with the burner 5 Check the HD...

Страница 33: ...e technical unit or place a Wi Fi repeater You have not entered the Wi Fi settings correctly in the app Check the Wi Fi settings Erase the added room from the app Reset the iMatch interface and try ag...

Страница 34: ...he gas fire Flue duct configurations 1 to 6 Flue duct configurations G20 25 Flue duct configurations G30 Product card Restrictor plates G20 G25 and G30 Configuration decorative elements Wiring diagram...

Страница 35: ...ion 4b reducerduct with roof pass through Configuration 5a diagonal duct with roof pass through Configuration 5b diagonal duct with rejuvenation and roof pass through Configuration 5c rejuvenation dia...

Страница 36: ...A 2 Flue duct configurations G20 G25 The various flue pipe configurations are indicated in configuration 1 through 6 See Flue duct configurations 1 through 6 36...

Страница 37: ...ical elbow Horizontal section max m 5 5 5 5 5 3 3 3 3 3 3 90 vertical elbow Connector 130 200 100 150 C Vertical 100 150 min 1 m Roof pass through B Remove the ceiling plate Configuration 4b 1st metre...

Страница 38: ...A 3 Flue duct configurations G30 The various flue pipe configurations are indicated in configuration 1 through 6 See flue duct configurations 1 through 6 38...

Страница 39: ...5 3 3 3 3 3 90 vertical elbow Connector 130 200 100 150 C Vertical 100 150 min 1 m Roof pass through B Remove the ceiling plate Configuration 4b 1st metre vertical min 0 5 m 90 vertical elbow Horizon...

Страница 40: ...C 11 3 kW n a 79 82 0 79 6 Kalfire GP60 59F Kalfire GP65 55C Kalfire GP70 55S G25 D 6 2 kW n a 72 76 1 62 7 Kalfire GP60 59F Kalfire GP65 55C Kalfire GP70 55S G20 D 6 1 kW n a 72 76 0 66 7 Kalfire GP6...

Страница 41: ...ounted below this value Appliances If the result of a chimney calculation is more than 5 5 mount the restrictor plate below G20 G25 G30 G60 48F G65 44C G70 44S 50 45 35 G80 48F G85 44C G90 44S 71 68 5...

Страница 42: ...ctions It is prohibited to alter the number of decorative elements or the configuration thereof Such alterations can lead to hazardous situations with regard to fire safety Take the instructions into...

Страница 43: ...1 4 6 7 5 2 3 43...

Страница 44: ...alter the number of decorative elements or the configuration thereof Such alterations can lead to hazardous situations with regard to fire safety Take the instructions into account Safety instructions...

Страница 45: ...1 3 2 5 4 6 7 8 8 7 45...

Страница 46: ...e number of decorative elements or the configuration thereof Such alterations can lead to hazardous situations with regard to fire safety Take the instructions into account Safety instructions for dec...

Страница 47: ...1 9 4 7 3 8 5 6 2 10 47...

Страница 48: ...r of decorative elements or the configuration thereof Such alterations can lead to hazardous situations with regard to fire safety Take the instructions into account Safety instructions for decorative...

Страница 49: ...5 1 2 3 7 4 6 8 10 9 9 49...

Страница 50: ...alter the number of decorative elements or the configuration thereof Such alterations can lead to hazardous situations with regard to fire safety Take the instructions into account Safety instructions...

Страница 51: ...4 5 3 6 1 1 51...

Страница 52: ...7 2 7 7 2 2 8 52...

Страница 53: ...the number of decorative elements or the configuration thereof Such alterations can lead to hazardous situations with regard to fire safety Take the instructions into account Safety instructions for...

Страница 54: ...4 5 2 1 1 3 54...

Страница 55: ...9 8 6 7 1 55...

Страница 56: ...the number of decorative elements or the configuration thereof Such alterations can lead to hazardous situations with regard to fire safety Take the instructions into account Safety instructions for...

Страница 57: ...5 6 7 8 3 2 2 1 57...

Страница 58: ...9 4 4 8 58...

Страница 59: ...r of decorative elements or the configuration thereof Such alterations can lead to hazardous situations with regard to fire safety Take the instructions into account Safety instructions for decorative...

Страница 60: ...5 2 9 6 2 1 4 3 60...

Страница 61: ...7 7 10 11 8 61...

Страница 62: ...alter the number of decorative elements or the configuration thereof Such alterations can lead to hazardous situations with regard to fire safety Take the instructions into account Safety instructions...

Страница 63: ...1 7 7 3 4 6 2 7 63...

Страница 64: ...2 4 4 5 5 8 64...

Страница 65: ...decorative elements or the configuration thereof Such alterations can lead to hazardous situations with regard to fire safety Take the instructions into account Safety instructions for decorative ele...

Страница 66: ...7 4 5 6 1 8 9 66...

Страница 67: ...3 3 11 2 10 10 12 67...

Страница 68: ...ative elements or the configuration thereof Such alterations can lead to hazardous situations with regard to fire safety Take the instructions into account Safety instructions for decorative elements...

Страница 69: ...1 2 6 6 8 8 9 7 7 4 With gas type G30 log 4 to be placed at extreme right 3 4 5 11 69...

Страница 70: ...ments must be placed according to the instructions It is prohibited to alter the number of decorative elements or the configuration thereof Such alterations can lead to hazardous situations with regar...

Страница 71: ...75 59F GP80 55C GP85 55S Number Amount Description Number Amount Description 1 1 H075680 8 1 F060687 2 1 H075681 9 Glass pebbles 3 1 H075682 10 1 HO75714 4 5 Logs 11 3 H075715 6 1 F060684 12 1 H075716...

Страница 72: ...10 2 1 9 11 3 3 4 5 5 7 6 72...

Страница 73: ...13 12 12 12 8 73...

Страница 74: ...e number of decorative elements or the configuration thereof Such alterations can lead to hazardous situations with regard to fire safety Take the instructions into account Safety instructions for dec...

Страница 75: ...ire GP80 54T GP85 50R Number Amount Description 1 2 3 Logs 4 1 H075680 5 1 H385418 6 1 H160692 7 1 F060684 8 1 F160679 9 1 H385419 10 1 H75127 11 1 F160681 12 1 F060686 13 Glass pebbles 14 4 H075715 1...

Страница 76: ...3 1 6 5 4 2 13 76...

Страница 77: ...14 7 10 11 8 12 12 Other side Divide 15 cryptonite and 16 ash 77...

Страница 78: ...er of decorative elements or the configuration thereof Such alterations can lead to hazardous situations with regard to fire safety Take the instructions into account Safety instructions for decorativ...

Страница 79: ...5C GP115 55S Number Amount Description Number Amount Description 1 2 Logs 9 1 F060686 3 1 H075680 10 1 F060684 4 1 H075681 11 Glass pebbles 5 1 H075682 12 4 H075715 6 2 H10555680 13 1 H075716 7 1 F160...

Страница 80: ...3 4 5 7 1 3 4 5 6 1 4 5 1 3 4 1 3 2 1 2 3 1 3 1 2 4 5 1 6 2 6 7 14 12 11 11 3 80...

Страница 81: ...3 4 5 7 8 1 3 4 7 9 10 8 3 4 5 6 7 8 1 3 4 5 6 7 8 1 3 4 5 6 7 1 9 10 8 15 13 81...

Страница 82: ...of decorative elements or the configuration thereof Such alterations can lead to hazardous situations with regard to fire safety Take the instructions into account Safety instructions for decorative...

Страница 83: ...115 75S Number Amount Description Number Amount Description 1 1 H10575676 H075681 H075680 10 1 H10572678 2 1 H075682 11 Glass pebbles 3 4 5 Logs 12 4 H075715 6 2 F060684 13 1 H075716 7 1 F060683 14 1...

Страница 84: ...4 3 5 2 3 4 5 1 2 3 4 5 1 1 2 3 4 1 1 2 1 1 1 2 1 1 1 1 1 2 3 4 5 6 6 1 1 1 14 11 84...

Страница 85: ...2 7 10 8 3 4 6 5 2 7 10 8 9 3 4 6 5 1 2 7 10 8 9 3 4 6 5 1 2 7 10 8 3 4 6 5 1 2 10 3 4 6 5 1 2 2 3 3 4 4 6 5 5 1 1 7 8 9 10 12 12 15 13 85...

Страница 86: ...A 7 Wiring diagram Wiring diagram Natural Spark Generator in the technical unit Fig 31 Wiring diagram HCB only applicable in hybrid mode and or Natural Spark Generator 86...

Страница 87: ...Wiring diagram for SDS domo cable as shut down switch Fig 32 SDS domo cable shut down switch 87...

Страница 88: ...G30 28 30 mbar 7 3 0 22 1 7 1 5 14 6 1 8 5 5 1 D A 13B P G30 50 mbar 7 4 0 23 1 4 1 5 15 2 2 5 6 1 D A NOX class 4 KALFIRE G80 59F G88 55C G90 55S Gas cat Gas type Connection pressure Load MAX Hi kw i...

Страница 89: ...4 0 35 None 1 3 28 4 2 7 8 4 22 D A 13B P G30 50 mbar 13 0 0 40 2 1 1 3 31 9 7 8 9 5 22 D A NOX class 4 Kalfire G120 41F G125 37C G130 37S Gas cat Gas type Connection pressure Load MAX Hi kW input Use...

Страница 90: ...13B P G30 28 30 mbar 9 4 0 29 2 0 3x1 0 0 5 18 0 8 2 7 6 2 D B 13B P G30 50 mbar 9 4 0 29 2 0 3x1 0 0 5 18 0 8 2 7 6 2 D B NOX class 5 Kalfire G160 41F G165 37C G170 37S Gas cat Gas type Connection pr...

Страница 91: ...mbar 10 3 1 09 3 5 3x1 6 0 8 14 2 4 6 7 9 2 D A 12E G25 G20 25mbar 20 mbar 10 3 10 3 1 09 1 09 3 5 3 5 3x1 6 0 8 3x1 6 0 8 14 2 14 2 4 6 4 6 7 9 7 9 2 2 D D A A I2 43 46 45 3 MJ m3 0 C I2K G25 3 25mba...

Страница 92: ...9 1 47 3 9 2x 1 6 1 8 12 8 9 5 10 7 1 C C A A I2 43 46 45 3 MJ m3 0 C I2K G25 3 25 mbar 12 8 1 6 3 9 2x 1 6 1 8 14 6 11 2 10 5 1 C A I2ELL G20 20mbar 13 9 1 47 3 9 2x 1 6 1 8 12 8 9 5 10 7 1 C A I2EL...

Страница 93: ...Kalfire GP105 59F GP110 55C GP115 55S Kalfire GP105 79F GP110 75C GP115 75S Kalfire G60 48F G65 44C G70 44S Kalfire G80 48F G85 55C G90 55S Kalfire G100 41F G105 37C G11037S Kalfire G120 41F G125 37C...

Страница 94: ...94...

Страница 95: ...95...

Страница 96: ...Gelo rveldweg 21 5951 DH Belfeld info kalfire nl KALFIRE COM DON T COMPROMISE REF V01 2019 EN...

Отзывы: