4. Mounting and installation
11
4.3.2
Wall duct C11
For distances to adjoining walls, coverings and windows, please
refer to the national legislation.
4.3.3
Roof duct C31
When placing the roof duct ensure no air turbulence can occur in
the mounting area. For this reason, always leave enough space
between the wall/roof and the roof duct.
4.3.4
Roof duct existing flue duct C31S
With an existing flue duct, you can use two connectors.
At the top use the ventilation plate with a draught
increasing hood. Connect a flue liner or flexible flue liner to
this, fitted through the existing duct.
Check the flue duct for any leaks which may cause under
pressure. In turn this will prevent the closed system from
functioning properly.
With a very old flue, use two flexible pipes. The inner pipe
must be centred in the middle, to prevent blockages.
At the entrance to the flue duct, mount the cover plate.
Ensure this is well sealed.
For distances to adjoining walls, coverings and windows, please
refer to the national legislation.
Содержание Fairo 90
Страница 10: ...3 Technical specifications 6 Electric connection data 230V 50Hz 12 mA 3W maximum ...
Страница 27: ...5 Preparing for use 23 Positioned log set Fairo 90 3 sided Front side view step 4 10 6 9 ...
Страница 39: ...7 Maintenance 35 5 Replace the cover strip in the appliance 6 Replace both side strips in the appliance ...
Страница 43: ...7 Maintenance 39 5 Replace the cover strip 6 Replace both side strips ...
Страница 49: ...APPENDIX B Connection diagram B1 APPENDIX B Connection diagram GND Fairo ...
Страница 53: ...APPENDIX C Dimension diagrams C5 All dimensions shown in mm Dimensions subject to modification Side view ...