6. Operation
30
11.
Press or to set the second switch on
time.
12.
Press to confirm this time. The
second temperature setpoint starts
flashing.
13.
Press or to set the second
temperature setpoint.
14.
Press to confirm the second
temperature setpoint. The system will
automatically jump to the next day.
15.
Repeat steps 7 thru 14 for the other six
days.
16.
Press to leave the menu.
Switching off the Fairo
If you are not in the basic menu, press to access the basic
menu. Switch off the Fairo by pressing .
Reset after a malfunction
If the system does not detect any flames
after 30 seconds of sparks or the display
shown appears, then there is a malfunction.
Reset the system by pressing on and
simultaneously. This can be attempted 3x,
afterwards the Fairo will enter malfunction
mode
for 24 hours. For code explanation,
see chapter 8.
1 2 3 4 5 6 7
15:00
II
18.0
°
C
11
12
13
1 2 3 4 5 6 7
15:00
II
18.0
°
C
1 2 3 4 5 6 7
15:00
II
14
1 2 3 4 5 6 7
07:00
II
22.0
°
C
xx
F 13
Reset
Содержание Fairo 90
Страница 10: ...3 Technical specifications 6 Electric connection data 230V 50Hz 12 mA 3W maximum ...
Страница 27: ...5 Preparing for use 23 Positioned log set Fairo 90 3 sided Front side view step 4 10 6 9 ...
Страница 39: ...7 Maintenance 35 5 Replace the cover strip in the appliance 6 Replace both side strips in the appliance ...
Страница 43: ...7 Maintenance 39 5 Replace the cover strip 6 Replace both side strips ...
Страница 49: ...APPENDIX B Connection diagram B1 APPENDIX B Connection diagram GND Fairo ...
Страница 53: ...APPENDIX C Dimension diagrams C5 All dimensions shown in mm Dimensions subject to modification Side view ...