8. Trouble shooting
42
8
Trouble shooting (for the installer only)
F14/F13/
F12/F08:
Fairo with no
ionization.
Does the Fairo
ignite?
Does the ignition
pin spark visibly
when the
appliance is
ignited?
N
N
N
N
Is there gas?
Do you hear
the gas flow
when the Fairo
is ignited?
Y
Measure the gas
pressure and check
the pipes for
obstructions.
Everything OK?
Y
Y
N
Check if the ceramic logs,
chips and stones are
positioned correctly and
that the distance between
the ignition pin and the
burner is 4-5 mm.
Ensure the pin is not covered, so
the flame can heat the pin. If the
Fairo only extinguishes after a
while, ensure the restrictor plate is
correctly set. Check recirculation.
Does the flame
touch the ionisation pin
at the moment an error
message is given?
N
Y
Check if the earth, phase
and zero are present. The
electronics will not work on
a 2-phase network or
without an earth. Turn the
plug. The Fairo is phase
sensitive. Is it correctly
connected?
Is the ignition cable loose?
Automatic burner faulty?
Gas block
faulty?
Ensure this is correctly connected by
an electrician. Use a prepared
separation transformer (ygas2100) to
make a 2-phase network or
a 1-phase network.
Measure the gas
block V1 and V2.
Is this ~4k
Ω
?
Y
Y
N
N
Y
N
Check if the
distance between
the ignition pin
and burner is 4-5
mm. Does the
pin spark in the
wrong place?
Содержание Fairo 90
Страница 10: ...3 Technical specifications 6 Electric connection data 230V 50Hz 12 mA 3W maximum ...
Страница 27: ...5 Preparing for use 23 Positioned log set Fairo 90 3 sided Front side view step 4 10 6 9 ...
Страница 39: ...7 Maintenance 35 5 Replace the cover strip in the appliance 6 Replace both side strips in the appliance ...
Страница 43: ...7 Maintenance 39 5 Replace the cover strip 6 Replace both side strips ...
Страница 49: ...APPENDIX B Connection diagram B1 APPENDIX B Connection diagram GND Fairo ...
Страница 53: ...APPENDIX C Dimension diagrams C5 All dimensions shown in mm Dimensions subject to modification Side view ...