12
EN
Adjustment of the minimum setting
following conversion to a different gas type
Conversion from natural gas to LPG
Ovens with stainless steel front:
Turn the temperature control knob to the
minimum position,
Then remove the knob. Insert a screwdriver
through the aperture to engage the bypass
screw
1
,
Turn the screw fully to the right.
Ovens with glass fronts:
Turn the temperature control knob to the
minimum position,
Remove the front by unscrewing the two
ring nuts,
Insert a screwdriver through the hole in the
front wall of the oven and turn the screw
1
fully clockwise.
Conversion from LPG to natural gas
Turn the oven temperature control knob to
the „Minimum“ position and allow the
appliance to warm up for about 10 minutes,
Then turn the bypass screw anticlockwise
to a obtain a low but stable flame,
Replace the front.
Attention!
After converting the appliance
to a different type of gas, remember to
change the data plate
2
to one with the
new data (gas type and pressure)
1
2