Controller
Electrical Control System
163
control will return to
the initial settings.(Use a φ1mm little round stick to push the button )
7. AIR DIRECTION Button:
Push this button, the louver can be fixed at a desired angle. The louver swing
(upward or downward) to a certain angle for each press. When the louvers swing at an angle which
would affect the cooling and heating efficiency of the air conditioner, it would automatically change the
swing direction (upward or downward).
8. FAN SPEED Button:
Fan speed will be selected in following sequence once pressing this button:
AUTO
LOW
MED
HIGH
9.
TIMER ON Button:
Press this button to preset the time ON(start to operate). Each press will increase the
time ON setting in 30minutes increments. When the setting time displays 10:00, each
press will increase the time ON setting in 60 minutes increments. To cancel the time ON program, simply
adjust the time ON to 0:00.
10. ECONOMIC RUNNING Button:
Press this button to go into the energy-Saving operation mode. Press
the button again to cancel.
11. TIMER OFF Button:
Press this button to preset the time OFF (turn off the operation). Each press will
increase the time OFF setting in 30 minutes increments. When the setting time displays 10:00, each press
will increase the time OFF setting in 60 minutes increments. To cancel the time OFF program, simply adjust
the time OFF to 0:00
12. LOCK Button:
Push this button to lock in all the current settings. To release settings, push again. (Use
a φ1mm little round stick to push this button)
13. POWERFUL Button:
Press this button on cooling/heating mode to go into powerful cooling (heating
operation. Press again to cancel it.
Note:
The unit will automatically revert back to the previous operational mode after continuously operating
under the powerful cooling mode.
Содержание KOU-12HFN1-QRC8
Страница 1: ...Contents i Energy Related Products SUPER DC INVERTER SERIES Service Manual 2013 LFIS B 1309...
Страница 2: ......
Страница 4: ......
Страница 17: ...Service Space Indoor Units 13 3 Service Space 1000mm 1000mm 1000mm 1000m m...
Страница 23: ...Field Wiring Indoor Units 19 9 Field Wiring...
Страница 31: ...Wiring Diagrams Indoor Units 27 KTB 24HWDN1 QRC4...
Страница 42: ...Service Space 38 Indoor Units 3 Service Space...
Страница 44: ...Wiring Diagrams 40 Indoor Units KUE 36HRFN1 QRC8 A...
Страница 47: ...Indoor Units 43 9 Field Wiring...
Страница 50: ...Dimensions 46 Indoor Units 2 Dimensions...
Страница 51: ...Service Space Indoor Units 47 3 Service Space...
Страница 52: ...Wiring Diagrams 48 Indoor Units 4 Wiring Diagrams KCA2U 12HRFN1 QRC8 KCA2 18HRFN1 QRC8...
Страница 56: ...52 Indoor Units 10 Field Wiring KCA2U 12HRFN1 QRC8 KCA2 18HRFN1 QRC8...
Страница 58: ......
Страница 61: ...Dimensions Console Type 57 2 Dimensions KFAU 12HRFN1 QRC8 KFA 16HRFN1 QRC8...
Страница 62: ...Service Space 58 Console Type 3 Service Space...
Страница 63: ...Wiring Diagrams Console Type 59 4 Wiring Diagrams KFAU 12HRFN1 QRC8 KFA 16HRFN1 QRC8...
Страница 68: ...Field Wiring 64 Console Type 10 Field Wiring KFAU 12HRFN1 QRC8 KFA 16HRFN1 QRC8...
Страница 74: ...Wiring Diagrams 70 Outdoor Units 4 Wiring Diagrams KOU 12HFN1 QRC8...
Страница 76: ...Wiring Diagrams 72 Outdoor Units KOU 36HFN1 RRC4 KOU 36HFN1 RRC8 520 KOU 36HFN1 QRC8 5A0...
Страница 77: ...Wiring Diagrams Outdoor Units 73 KOU 36HFN1 RRC8 5A0...
Страница 102: ...Refrigerant pipe installation 98 Installation...
Страница 110: ...Engineering of insulation 106 Installation cause leakage to damage the house decoration...