Controller
160
Electrical Control System
3.1.2 RG51C/E
Remote Controller Specifications
Model
RG51C/E
Rated Voltage
3.0V(2pieces of LR03 7
#
batteries)
Lowest Voltage of CPU Emitting Signal
2.0V
Reaching Distance
8m (when using 3.0 voltage, it can get 11m)
Environment Temperature Range
-5
℃
~
60
℃
Introduction of Function Buttons on the Remote Controller
ADJUST
AU TO
COOL
DR Y
HE AT
FAN
HIGH
MED
LOW
MODE
SWING
FAN SPEED
TIMER ON
ECO
ON/OFF
TI MER OFF
RESET LOC K
2
1
4
5
3
7
8
9
10
11
SET TEM PERATURE( C)
12
Adju st
Mod e sett in g
Adj ust
ON/ OFF
TI MER ON
TIME R OFF
L ock
Econom ic ope rat ion
Fan speed se tt ing
SWING
AI R
DIRECTI ON
Re s et
13
1. Adjust
: Decrease the set temp. Keeping pressing will decrease the temp with 1
℃
per 0.5s.
2. Adjust
: Increase the set temp. Keeping pressing will increase the temp with 1
℃
per 0.5s.
3. MODE
: Once pressing, running mode will be selected in the following sequence:
AUTO
COOL
DRY
HEAT
FAN
NOTE: No heating mode for cool only type unit.
4. VERT SWING:
Used to stop or start horizontal louver movement. The louver will swing up and down
automatically if push this button.
AIR DIRECTION
: Used to set the desired up/down air flow direction. The louver changes 6 degree in
angle for each press.
5. HORIZ SWING:
Used to stop or start vertical louver movement.
6. FAN SPEED+ MODE
: Press the Mode and Fan speed button simultaneously for 2 seconds. The remote
Содержание KOU-12HFN1-QRC8
Страница 1: ...Contents i Energy Related Products SUPER DC INVERTER SERIES Service Manual 2013 LFIS B 1309...
Страница 2: ......
Страница 4: ......
Страница 17: ...Service Space Indoor Units 13 3 Service Space 1000mm 1000mm 1000mm 1000m m...
Страница 23: ...Field Wiring Indoor Units 19 9 Field Wiring...
Страница 31: ...Wiring Diagrams Indoor Units 27 KTB 24HWDN1 QRC4...
Страница 42: ...Service Space 38 Indoor Units 3 Service Space...
Страница 44: ...Wiring Diagrams 40 Indoor Units KUE 36HRFN1 QRC8 A...
Страница 47: ...Indoor Units 43 9 Field Wiring...
Страница 50: ...Dimensions 46 Indoor Units 2 Dimensions...
Страница 51: ...Service Space Indoor Units 47 3 Service Space...
Страница 52: ...Wiring Diagrams 48 Indoor Units 4 Wiring Diagrams KCA2U 12HRFN1 QRC8 KCA2 18HRFN1 QRC8...
Страница 56: ...52 Indoor Units 10 Field Wiring KCA2U 12HRFN1 QRC8 KCA2 18HRFN1 QRC8...
Страница 58: ......
Страница 61: ...Dimensions Console Type 57 2 Dimensions KFAU 12HRFN1 QRC8 KFA 16HRFN1 QRC8...
Страница 62: ...Service Space 58 Console Type 3 Service Space...
Страница 63: ...Wiring Diagrams Console Type 59 4 Wiring Diagrams KFAU 12HRFN1 QRC8 KFA 16HRFN1 QRC8...
Страница 68: ...Field Wiring 64 Console Type 10 Field Wiring KFAU 12HRFN1 QRC8 KFA 16HRFN1 QRC8...
Страница 74: ...Wiring Diagrams 70 Outdoor Units 4 Wiring Diagrams KOU 12HFN1 QRC8...
Страница 76: ...Wiring Diagrams 72 Outdoor Units KOU 36HFN1 RRC4 KOU 36HFN1 RRC8 520 KOU 36HFN1 QRC8 5A0...
Страница 77: ...Wiring Diagrams Outdoor Units 73 KOU 36HFN1 RRC8 5A0...
Страница 102: ...Refrigerant pipe installation 98 Installation...
Страница 110: ...Engineering of insulation 106 Installation cause leakage to damage the house decoration...