Open the TP valve handle on a regular (about one month) basis to check
whether it is blocked. Perform sewage disposal by following the guide on a
regular (about once a year) basis.
Notes: The TP valve provided by user.
It is normal that the TP valve drips.
T
he pressure relief opening of the TP valve must be connected to one end
of a securely fixed guide hose, and the other end is connected to the floor
drain.
Ensure that the guide hose is not twisted or folded.
You are advised to install the filter horizontally after the main shutoff valve of
the user’s water pipe. Ensure that the direction indicated by the arrow on the
filter must be the same as the water flow. If impurities inside the waterway
need to be cleared, open the end cap of the filter.
When the filter is installed vertically, the direction indicated by the arrow must
not be upward and the end cap must be placed slantwise downwards.
This marking indicates that this product should not be disposed with other
household wastes throughout the EU. To prevent possible harm to the envi
-
ronment or human health from uncontrolled waste disposal, recycle it possibly
to promote the sustainable reuse of material resources. To return you used de
-
vice, please use the return and collection systems or contact the retailer where
the product was purchased. They can take this product for environmental safe
recycling.
Содержание KHP-2.4/D270
Страница 1: ......
Страница 16: ...16 www kaisai com PL 3 6 Schemat instalacji wodnej 3 7 Instrukcja instalacji zdalnego sterownika przewodowego ...
Страница 18: ...18 www kaisai com PL Rys 3 2 Instrukcja montażu sterownika przewodowego ...
Страница 71: ...71 AIR SOURCE HEAT PUMP WATER HEATER EN Fig 3 2 Sketch map for Installation Instruction of Wired Controller ...
Страница 88: ...88 www kaisai com EN CONTROLLER FOR THE AIR SOURCE HEAT PUMP WATER HEATER Owner s Manual XK64 ...
Страница 108: ......