©2012 Kaelus, Inc. All rights reserved
.
ACU0001F1V1-1 User Guide
27
4.2.2
RET Data & T ilt Adjustment
This section covers RET device details, RET device calibration and tilt angle
adjustment.
The following table describes the RET information items.
AISG V1.x RET (or AISG V2.x RET): shows the AISG version supported by the
device
Column Name
Description / Constraint
Device Status
Displays “OK” or alarm messages
RET Model Name
RET model name
RET Serial No.
RET serial number
Vendor
Vendor name
RET Hardware Version
RET hardware version
RET Software Version
RET software version
Min T ilt - Max T ilt
Allowed electrical down tilt range of the selected
antenna model
Current T ilt
Current electrical tilt. T ilt value must be in the Min
T ilt - Max T ilt range. If the tilt value cannot be
retrieved, the data value is empty.
4.2.2.1
Calibrate Device
After installation of a RET device, calibration causes the actuator to be
driven through its whole tilt range. Also, sometimes unforeseen errors
require calibration to return RET device to a normal status.
Click on the Calibrate button to calibrate the RET device