ACU0001F1V1-1 User Guide
11
Confirm and initiate the reboot process.
Wait for the process to end. You may need to reconnect to the ACU using
the new IP if the IP is changed.
3.1.2
System Information
The System Information section shows the Product Model, Serial No.,
Hardware Version and Software Version of the ACU system. The selected
user interface language can also be changed here. Select the preferred
language from the drop-down list and click the Set button to apply the
change.
3.1.3
Power Setting
In the Power Setting section, the power voltage and supply mode provided
to the connected AISG devices can be changed.
Field Name
Description / Constraint
Power Supply
DC 12V = 12VDC applied to PIN 1 of the AISG Controller
DC 24V = 24VDC applied to PIN 6 of the AISG Controller
Power Mode:
Always On = the power will be continuously on.
Power Save = Power will be applied to the AISG bus long
enough to complete an operation, then it will turn off