Electrical warnings

 •   Only use the specified power cord. If the power cord is damaged, it must be replaced by the manufacturer, certified  

service agent or licensed electrical contractor.

 •   Keep power plug clean. Remove any dust or grime that accumulates on or around the plug. Dirty plugs can cause fire  

or electric shock.

 • 

 Do  not

 pull power cord to unplug unit. Hold the plug firmly and pull it from the outlet. Pulling directly on the cord can  

damage it, which can lead to fire or electric shock.

 •   

Do not

 use an extension cord, manually extend the power cord, or connect other appliances to the same outlet as  

the air conditioner. Poor electrical connections, poor insulation, and insufficient voltage can cause fire.

Cleaning and maintenance warnings

•   Turn off the device and pull the plug before cleaning. Failure to do so can cause electrical shock.

•     

Do not

 clean the air conditioner with excessive amounts of water.

  •   

Do not

 clean the air conditioner with combustible cleaning agents. Combustible cleaning agents can  

cause fire or deformation.

  WARNING

 CAUTION

•   If the air conditioner is used together with burners or other heating devices, thoroughly ventilate the room  

to avoid oxygen deficiency.

•   If you are not going to use the air-conditioner for a long time, disconnect the power from the main isolator.

•   During storms or bad weather turn off the unit and disconnect the power from the main isolator.

•   Make sure that water condensation can drain unhindered from the unit.

•  

Do not

 operate the air conditioner with wet hands. This may cause electric shock.

• 

 Do  not

 use device for any other purpose than its intended use.

•  

Do not

 climb onto or place objects on top of the outdoor unit.

•     

Do not

 allow the air conditioner to operate for long periods of time with doors or windows open,  

or if the humidity is very high.

J3499_Kaden_Owners Manual_240817_V3.indd   4

28/08/2017   8:59 AM

Содержание KS09

Страница 1: ...Owner s Manual WALL MOUNTED AIR CONDITIONER KS09 KS12 KS18 KS24 KS28 KS Series J3499_Kaden_Owners Manual_240817_V3 indd 1 28 08 2017 8 59 AM...

Страница 2: ...mote 9 4 Care and Maintenance 10 5 Troubleshooting 12 Important note Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future r...

Страница 3: ...onal to install this air conditioner Inappropriate installation may cause water leakage electric shock or fire All repairs maintenance and relocation of this unit must be performed by a licensed servi...

Страница 4: ...cause electrical shock Do not clean the air conditioner with excessive amounts of water Do not clean the air conditioner with combustible cleaning agents Combustible cleaning agents can cause fire or...

Страница 5: ...f when defrosting when anti cold air feature is turned on when unit is self cleaning when freeze protection is turned on when Wireless Control feature is activated Display Code Meanings In Fan mode th...

Страница 6: ...perations must be carried out by a professional Louver Angle Memory When turning on your unit the louver will automatically resume its former angle Refrigerant Leakage Detection The indoor unit will a...

Страница 7: ...zontal SWING button once to activate the louvre Each time you press the button it will adjust the louvre by 6 Press the button until the direction you prefer is reached 2 To make the louvre swing side...

Страница 8: ...y 1 C after 1 hour and will increase an additional 1 C after another hour When in HEAT mode the unit will decrease the temperature by 1 C after 1 hour and will decrease an additional 1 C after another...

Страница 9: ...nually with the MANUAL CONTROL button located on the indoor unit Note that manual operation is not a long term solution and that operating the unit with your remote control is strongly recommended BEF...

Страница 10: ...light 6 When dry slide it back into the indoor unit Cleaning Your Indoor Unit Cleaning Your Air Filter CAUTION Only use a soft dry cloth to wipe the unit clean If the unit is especially dirty you can...

Страница 11: ...the power Remove batteries from remote control CAUTION Before changing the filter or cleaning turn off the unit and disconnect its power supply When removing filter do not touch metal parts in the un...

Страница 12: ...erature fluctuates again The indoor unit emits white mist In humid regions a large temperature difference between the room s air and the conditioned air can cause white mist Both the indoor and outdoo...

Страница 13: ...be emitted when the unit is turned on This can be mitigated by covering the unit during long periods of inactivity The unit emits a bad odor The unit may absorb odors from the environment such as fur...

Страница 14: ...either unit is blocked Turn the unit off remove the obstruction and turn it back on Doors and windows are open Make sure that all doors and windows are closed while operating the unit Excessive heat...

Страница 15: ...qualified service technician Poor heating performance The outdoor temperature is extremely low Use other heating device Cold air is entering through doors and windows Make sure that all doors and win...

Страница 16: ...J3499_Kaden_Owners Manual_240817_V3 indd 16 28 08 2017 8 59 AM...

Отзывы: