background image

Kaden Owners Manual  | 

15

Issue

Possible Causes

Possible Causes

The unit is not 
working

Power failure

Wait for the power to be restored

The power is turned off

Turn on the power

The fuse is burned out

Contact a qualified service technician

Remote control batteries are dead

Replace batteries

The Unit’s 3-minute protection has 
been activated

Wait three minutes after restarting the unit

Timer is activated

Turn timer off

The unit starts and 
stops frequently

There’s too much or too little refrigerant in  
the system

Contact a qualified service technician

Incompressible gas or moisture has entered  
the system.

Contact a qualified service technician

The compressor is broken

Contact a qualified service technician

The voltage is too high or too low

Contact a qualified service technician

Poor heating 
performance

The outdoor temperature is extremely low

Use other heating device

Cold air is entering through doors and windows

Make sure that all doors and windows  
are closed during use

Low refrigerant due to leak

Contact a qualified service technician

Indicator lamps 
continue flashing

Error code appears 
in the window 
display of indoor 
unit:

•  E0, E1, E2… 
•  P1, P2, P3… 
•  F1, F2, F3…

The unit may stop operation or continue to run safely.If the indicator lamps continue to  
flash or error codes appear, wait for about 10 minutes. The problem may resolve itself.  
If not, disconnect the power, then connect it again. Turn the unit on.

If the problem persists, disconnect the power and contact a qualified service technician.

Note

If your problem persists after performing the checks and diagnostics above, turn off your unit immediately and  
contact Customer Care 1800 080 055.

J3499_Kaden_Owners Manual_240817_V3.indd   15

28/08/2017   8:59 AM

Содержание KS09

Страница 1: ...Owner s Manual WALL MOUNTED AIR CONDITIONER KS09 KS12 KS18 KS24 KS28 KS Series J3499_Kaden_Owners Manual_240817_V3 indd 1 28 08 2017 8 59 AM...

Страница 2: ...mote 9 4 Care and Maintenance 10 5 Troubleshooting 12 Important note Read this manual carefully before installing or operating your new air conditioning unit Make sure to save this manual for future r...

Страница 3: ...onal to install this air conditioner Inappropriate installation may cause water leakage electric shock or fire All repairs maintenance and relocation of this unit must be performed by a licensed servi...

Страница 4: ...cause electrical shock Do not clean the air conditioner with excessive amounts of water Do not clean the air conditioner with combustible cleaning agents Combustible cleaning agents can cause fire or...

Страница 5: ...f when defrosting when anti cold air feature is turned on when unit is self cleaning when freeze protection is turned on when Wireless Control feature is activated Display Code Meanings In Fan mode th...

Страница 6: ...perations must be carried out by a professional Louver Angle Memory When turning on your unit the louver will automatically resume its former angle Refrigerant Leakage Detection The indoor unit will a...

Страница 7: ...zontal SWING button once to activate the louvre Each time you press the button it will adjust the louvre by 6 Press the button until the direction you prefer is reached 2 To make the louvre swing side...

Страница 8: ...y 1 C after 1 hour and will increase an additional 1 C after another hour When in HEAT mode the unit will decrease the temperature by 1 C after 1 hour and will decrease an additional 1 C after another...

Страница 9: ...nually with the MANUAL CONTROL button located on the indoor unit Note that manual operation is not a long term solution and that operating the unit with your remote control is strongly recommended BEF...

Страница 10: ...light 6 When dry slide it back into the indoor unit Cleaning Your Indoor Unit Cleaning Your Air Filter CAUTION Only use a soft dry cloth to wipe the unit clean If the unit is especially dirty you can...

Страница 11: ...the power Remove batteries from remote control CAUTION Before changing the filter or cleaning turn off the unit and disconnect its power supply When removing filter do not touch metal parts in the un...

Страница 12: ...erature fluctuates again The indoor unit emits white mist In humid regions a large temperature difference between the room s air and the conditioned air can cause white mist Both the indoor and outdoo...

Страница 13: ...be emitted when the unit is turned on This can be mitigated by covering the unit during long periods of inactivity The unit emits a bad odor The unit may absorb odors from the environment such as fur...

Страница 14: ...either unit is blocked Turn the unit off remove the obstruction and turn it back on Doors and windows are open Make sure that all doors and windows are closed while operating the unit Excessive heat...

Страница 15: ...qualified service technician Poor heating performance The outdoor temperature is extremely low Use other heating device Cold air is entering through doors and windows Make sure that all doors and win...

Страница 16: ...J3499_Kaden_Owners Manual_240817_V3 indd 16 28 08 2017 8 59 AM...

Отзывы: