Operating temperature
When your air conditioner is used outside of the following temperature ranges, certain safety protection features may activate and
cause the unit to disable.
FOR OUTDOOR UNITS WITH CRANKCASE
ELECTRIC HEATER
When outside temperature is below 0°C we strongly
recommend keeping the unit plugged in at all times to
ensure smooth ongoing performance.
NOTE:
If the air conditioner is operating in a room where the
relative humidity of the room is
less
than 80%, the surface of
the air conditioner may attract condensation. Please set the
vertical air flow louvre to its maximum angle (vertically to the
floor), and set HIGH fan mode.
To further optimise the performance of your unit,
do the following:
• Keep doors and windows closed.
• Limit energy usage by using TIMER ON and TIMER
OFF functions.
•
Do not
block air inlets or outlets.
• Arrange for a qualified service technician to inspect
and clean the air filters seasonally.
Do not
do it
yourself; it can be dangerous.
Features
Protection of the air conditioner
Compressor protection
The compressor cannot restart for 3 minutes after it stops.
Anti-cold air
The unit is designed to not blow cold air on HEAT mode, when
the indoor heat exchanger is in one of the following three
situations and the set temperature has not been reached.
1. When heating has just started.
2. During defrosting.
3. Low temperature heating.
The indoor or outdoor fan stops running when defrosting
(Cooling and heating models only).
Defrosting
Frost may be generated on the outdoor unit during a heat cycle
when outdoor temperature is low and humidity is high resulting
in lower heating efficiency in the air conditioner.
Under these conditions, the air conditioner will stop heating
operations and start defrosting automatically.
The time to defrost may vary from 4 to 10 minutes, depending
on the outdoor temperature and the amount of frost build-up
on the outdoor unit.
Auto-restart
In case of power failure, the system will immediately stop. If the
system has an auto restart function, the unit will restart using
the same settings.
COOL mode
HEAT mode
DRY mode
Room temperature
17°C – 32°C
0°C – 30°C
10°C – 32°C
Outdoor temperature
-15°C – 50°C
-15°C – 24°C
0°C – 50°C
Содержание KMC R32
Страница 1: ...Owner s and Controller Manual MULTI AIR CONDITIONER...
Страница 10: ...10 Kaden Owner s and Controller Manual...
Страница 11: ...Kaden Owner s and Controller Manual 11 KSI06 KSI09 KSI12 KSI18 KSI24 KSI28 KSI Split System Air Conditioner...
Страница 19: ...Kaden Owner s and Controller Manual 19 KMD Ducted Air Conditioner KMD09 KMD12 KMD18 KMD24...
Страница 24: ...24 Kaden Owner s and Controller Manual...
Страница 25: ...Kaden Owner s and Controller Manual 25 KMC Cassette Air Conditioner KMC09 KMC12 KMC18...
Страница 30: ...30 Kaden Owner s and Controller Manual...
Страница 31: ...Kaden Owner s and Controller Manual 31 KM Multi Outdoor Unit KM24 KM28 KM46...
Страница 56: ...56 Kaden Owner s and Controller Manual...
Страница 68: ...kadenair com au...