4. Troubleshooting
SAFETY PRECAUTIONS
If any of the following conditions occurs, turn off your unit immediately!
• The power cord is damaged or abnormally warm.
• You smell a burning odour.
• The unit emits loud or abnormal sounds.
• A power fuse blows or the circuit breaker frequently trips.
• Water or other objects fall into or out of the unit.
DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT AN AUTHORISED TECHNICIAN IMMEDIATELY!
Common issues
The following problems are not a malfunction and in most situations will not require repairs.
Issue
Possible causes
Unit does not turn on when
pressing ON/OFF button
The unit has a 3-minute protection feature that prevents the unit from overloading. The unit
cannot be restarted within three minutes of being turned off.
Cooling and heating models: If the Operation light and PRE-DEF (Pre-heating/Defrost) indicators
are lit up, the outdoor temperature is too cold and the unit’s anti-cold function is activated in order
to defrost the unit.
In cooling-only models: If the “Fan Only” indicator is lit up, the outdoor temperature is too cold
and the unit’s anti-freeze protection is activated in order to defrost the unit.
The unit changes from
COOL/HEAT mode to FAN
mode
The unit may change its setting to prevent frost from forming on the unit. Once the temperature
increases, the unit will start operating in the previously selected mode again.
The set temperature has been reached, at which point the unit turns off the compressor. The unit
will continue operating when the temperature fluctuates again.
The indoor unit emits white
mist
In humid regions, a large temperature difference between the room’s air and the conditioned air
can cause white mist.
Both the indoor and outdoor
units emit white mist
When the unit restarts in HEAT mode after defrosting, white mist may be emitted due to moisture
generated from the defrosting process.
The indoor unit makes noises A rushing air sound may occur when the louvre resets its position.
A squeaking sound is heard when the system is OFF or in COOL mode. The noise is also heard
when the drain pump (optional) is in operation.
A squeaking sound may occur after running the unit in HEAT mode due to expansion and
contraction of the unit’s plastic parts.
Both the indoor unit and
outdoor unit make noises
Low hissing sound during operation: This is normal and is caused by refrigerant gas flowing
through both indoor and outdoor units.
Low hissing sound when the system starts, has just stopped running, or is defrosting: This noise
is normal and is caused by the refrigerant gas stopping or changing direction.
Squeaking sound: Normal expansion and contraction of plastic and metal parts caused by
temperature changes during operation can cause squeaking noises.
Содержание KMC R32
Страница 1: ...Owner s and Controller Manual MULTI AIR CONDITIONER...
Страница 10: ...10 Kaden Owner s and Controller Manual...
Страница 11: ...Kaden Owner s and Controller Manual 11 KSI06 KSI09 KSI12 KSI18 KSI24 KSI28 KSI Split System Air Conditioner...
Страница 19: ...Kaden Owner s and Controller Manual 19 KMD Ducted Air Conditioner KMD09 KMD12 KMD18 KMD24...
Страница 24: ...24 Kaden Owner s and Controller Manual...
Страница 25: ...Kaden Owner s and Controller Manual 25 KMC Cassette Air Conditioner KMC09 KMC12 KMC18...
Страница 30: ...30 Kaden Owner s and Controller Manual...
Страница 31: ...Kaden Owner s and Controller Manual 31 KM Multi Outdoor Unit KM24 KM28 KM46...
Страница 56: ...56 Kaden Owner s and Controller Manual...
Страница 68: ...kadenair com au...