Page 7
KACO blueplanet 3.0 NX1 M2 KACO blueplanet 3.7 NX1 M2 KACO blueplanet 4.0 NX1 M2
KACO blueplanet 5.0 NX1 M2
Fig. 15:
Cable configuration
1 Cable requirements are as follows. Insert the conductor into a suitable ferrule according to DIN 46228-4 and crimp
the contact.
Fig. 16:
Remove communication plate
2 Remove the communication plate and replace it.
Fig. 17:
Cable configuration
3 Loosen the swivel nut of the cable gland on the communication plate
4 Remove the sealing plug and lead the stripped cable through the swivel nut, sealing sleeve, communication plate,
and the cable through the magnetic ring with three turns
5 Press the latch of the smart meter terminal and insert the conductors accordingly.
6 Make sure the cable is connected firmly.
Fig. 18 Insert smart meter terminal to the socket
7 Insert the smart meter terminal to the socket, screw communication plate to the inverter and tighten the swivel
nut. Screwdriver type: PH2, torque: 1.6Nm.