Use r ma nual Ka bola B-serie, 1-4-2005 

14

 

 Appendix A Technical specifications 

 
 

 
 
 
 
 
 
 
 
 
 
 

Type 

B-8 

B-12 

B-17 

B-25 

B-35 

B-45 

B-55 

B-70 

B-80 

B-100 

505 

600 

670 

970 

970 

970 

970 

1165 

1165 

1165 

343 

347 

411 

455 

455 

445 

485 

487 

487 

488 

115 

115 

115 

115 

125 

125 

356 

361 

416 

466 

468 

488 

498 

508 

508 

498 

235 

243 

364 

283 

284 

284 

384 

314 

314 

314 

320 

343 

408 

388 

491 

580 

697 

699 

839 

1050 

70 

70 

70 

70 

70 

70 

70 

70 

70 

70 

310 

325 

325 

385 

385 

385 

385 

385 

385 

460 

336 

361 

416 

396 

503 

593 

708 

708 

858 

1058 

400 

480 

548 

753 

754 

754 

759 

961 

963 

963 

Flue gas ø 

80 

80 

80 

100 

125 

150 

150 

180 

180 

200 

Fluegas temp °C 

160-200 

180-240 

180-240 

180-220 

180-230 

180-230 

180-240 

180-240 

180-250 

180-260 

C.H.-connection 

1” 

1” 

1”  

5/4” 

1½ ”  

1½” 

2” 

2” 

2” 

2” 

IP-value 

50-11 

Burner 

 230 V  

 

  24 V 

2-B009 
3-C012 

2-B010 
3-C013 

2-B011 
3-C014 

2-B012 
3-C015 

2-B013 
3-C016 

2-B014 
3-C017 

2-B014 

2-B016 

2-B017 

 

Nozzle 60° 

0.30 

0.40 

0.50 

0.85 

1.00 

1.25 

1.50 

1.75 

1.75 

2.00 

Nom. Capacity kW min 
 

 

max 

11 

11.2 

14 

14 

19.7 

19.7 

29 

29 

40.7 

40.7 
52.3 

51.1 
63.9 

63.9 
81.4 

74.4 

93 

93 

116.3 

Max oil consumption kg/h 

1.1 

1.4 

1.9 

3.3 

3.7 

5.2 

6.5 

7.5 

8.4 

10.3 

Testpressure in bar 

Operating pressure in bar 

Weight in kg 

50 

65 

94 

118 

140 

155 

178 

270 

309 

445 

Water volume in l 

12 

16 

18 

23 

26 

36 

55 

68 

82 

Temperature control range 

35-90 

35-90 

35-90 

35-90 

35-90 

35-90 

35-90 

35-90 

35-90 

35-90 

Isolation thickness in mm 

30 

30 

30 

50 

50 

50 

50 

50 

50 

50 

Fuel 

HBO 1, HBO 2, diesel of  gasolie 

Burning ef f iciency in % 

96 

91 

91 

92 

92 

92 

91 

91 

91 

91 

Waterside ef f iciency % 

92 

87 

88 

89 

89 

89 

88 

88 

88 

88 

Standby loss 

3 % 

 

 

Содержание B-8

Страница 1: ......

Страница 2: ...ay Hint This gives the user suggestions and advises to facilitate the execution of certain tasks Attention Additional information is supplied to the user and possible problems are indicated Warning Wa...

Страница 3: ...al heating system 7 4 1 3 Flue gas outlet 7 4 1 4 Electrical installation 8 4 1 5 Filling the central heating system 9 4 1 6 Mounting the burner 10 4 1 7 Connecting the oil filter and oil burner 11 4...

Страница 4: ...ation These boilers are not designed for direct heating of the rooms in which they are installed 1 3 Product description The B Series boilers heat the central heating water by means of a pressure jet...

Страница 5: ...be complied with when operating the B Series boilers Measures for a safe installation Don t store any flammable and or gaseous products in the room where the boiler is installed to avoid explosions a...

Страница 6: ...burner Store the boiler standing up Store the boiler on a firm horizontal base 4 Installing and preparing for first use In this chapter you will find directions and hints for a correct placement and f...

Страница 7: ...arts where contact with human body parts is possible For a correct flue gas outlet the following points need to be observed Use the proper length diameter dimensions use a diameter equal to the diamet...

Страница 8: ...5 elbows of 90 The maximum allowed length is 10 metres Every elbow of 90 counts as 1 metre Outside use double walled chimney pipe Hint To reduce the noise resulting from flames it is wise to install...

Страница 9: ...res to points 5 and 6 of the connector should conform to the values in table 1 Table 1 Distance to the battery Core diameter 6 metres 6 mm 15 metres 10 mm 4 1 5 Filling the central heating system The...

Страница 10: ...a B12 you need to saw an extra piece off the flange The mounting of the burner is done in the following way 1 Place the nut for the flange bolt in the dedicated position and place the gasket 2 Mount...

Страница 11: ...nnect the fuel line from the tank to the filter 5A The fuel line must have a outer diameter of 8mm and must be made from copper or steel The fuel has to be connected directly to the oil tank Correct f...

Страница 12: ...button 8 and return to 5 4 repeat if necessary 5 9 Close the bleeding 3B when only oil and no bubbles come out of the hose Attention The oil burner is tested by the manufacturer not adjusted The adjus...

Страница 13: ...pes with a thin metal strip Attention Don t use any aggressive solvents like thinner or gasoline 1 9 Clean the boiler with a vacuum cleaner 1 10 Replace the boiler top if necessary use a new gasket 1...

Страница 14: ...ection 1 1 1 5 4 1 1 2 2 2 2 IP value 50 11 Burner 230 V 24 V 2 B009 3 C012 2 B010 3 C013 2 B011 3 C014 2 B012 3 C015 2 B013 3 C016 2 B014 3 C017 2 B014 2 B016 2 B017 Nozzle 60 0 30 0 40 0 50 0 85 1 0...

Страница 15: ...ation pump 13 Seal Two 1 or bigger 14 Knee inner x outer thread Different per type 1x1 1 x1 or 1 x1 15 Pressure valve pressure gauge fill drain cock 16 T connection 1 x x1 Only for B 12 17 Fire inspec...

Страница 16: ...User manual Kabola B serie 1 4 2005 16 Appendix C Electrical diagram B8 B70 230V...

Страница 17: ...User manual Kabola B serie 1 4 2005 17 Appendix D Electrical diagram B80 B100 230V...

Страница 18: ...User manual Kabola B serie 1 4 2005 18 Appendix E Electrical diagram B8 B45 24V...

Страница 19: ...f flame protection Flame protection defect photo cell Replace flame protection Burner starts pulsing Flue glass flow interrupted Clear chimney opening Boiler dirty Clean boiler Oil supply interrupted...

Страница 20: ...User manual Kabola B serie 1 4 2005 20 Appendix G CE declaration...

Отзывы: