0639-990-21---30j_2010.07.indd
SLA
RESET?
To ?
Tn ?
Tvn ?
s ?
Vo ?
Vc ?
VERS ?
CYCLE?
LOCK ?
UNLOC?
T LCD?
0...45 s (Standard 1 s)
0...45 s (Standard 5 s)
0...90 s
10...100 %
100...600* mm/s
100...400* mm/s
0...300 s
Display
0639-990/22j
Page 23 of 46
Operating instructions
Description
Winter (reduced opening width)
Summer (entire opening width)
new setting-up of the drive unit
hold-open time Day
hold-open time night
Delay time for switching-over to night
reduced opening width (winter)
Opening speed
Closing speed
Software version
number of opening cycles
enable the keylock
Disable the keylock
Background lighting
Setting range
6.2.5
Menu level
Short and simultaneous actuation of both arrow keys (=access to the menu level).
Select the desired menu item bymeans of the arrow key.
Confirm by means of the OK key.
note:
* Depending on the wing weight, the maximum values will be reduced by the
system.
6.2.6
Priority of the parameters
DiP switch 6 must be switched to On if you want to be able to change the parameters by
means of the D-BeDiX (D-BeDiX fully functional). in this case the potentiometers will be
disregarded.
if the DiP switch 6 is Off, the potentiometer settings have prevalence. even though the
D-BEDIX allows a readout of the programmed values, their modification will not be posib
-
le (restricted functionality of the D-BeDiX).
The hold-open time niGhT can only be set by using D-BeDiX. The position of DiP-
Switch 6 is irrelevant.
if during the operation the DiP switch 6 is switched from On to Off, the potentiometer
settings will be immediately activated.
if the D-BeDiX is removed while the DiP switch 6 is On, the parameters remain
unchanged.
6.2.7
Parameter setting only by authorized persons
if you do not want the parameters to be changed by unauthorized persons, then DiP
switch 6 must be set to OFF, in which case a modification of the parameters by means of
the D-BeDiX is not possible.