Operating instructions
6
CONTROL
The door opening is performed automatically via radar or manually by means of a push-
button. The door is automatically closed as soon as the programmed hold-open time has
expired.
6.1
Key-operated program switch
The door command is carried out by a key-
operated program switch. This is attended
by a simple unnumbered key which is remo-
vable in any position.
further, a reset button/key is installed on the
key-operated program switch allowing to set
off a setting-up procedure.
The following operating modes can be
selected:
niGhT
The installation is locked
1
. As
opening command, only the key-
operated impulse switch (with key
function) is accepted.
AuTOmATiC
Automatic operation (summer or
winter
2
opening width). The instal-
lation is not locked.
mAnuAL
The installation opens. The sliding
wings are released and can be
shifted by hand.
eXiT
One-way traffic from inside to
-
wards the outside (inside = dri-
ve unit side). The installation is
locked
1
(shop closing switching
mode).
1
Provided that the locking mechanism (optional) is installed and DiP2 on Off.
2
For switching from summer to winter opening, an external switch can be connected to
the control unit.
Surface-type mounting
flush type mounting